Log In Log In  |  Checkout   |  42 item(s)
1 x 4042-K Male Elbow Fitting Compression type(membrane housing use)
2 x 752, DC Booster Pump w/ Transformer
1 x 709, Automatic Shut Off Valve 4-way Four Way Valve
1 x 531, PAE RO Storage Pressure Osmosis Water Tank Container 3G
1 x 1st stage SF05 sediment filter (replace every 6-12 months)
1 x 733, Built-in Pressure Gauge 0 to 150 psi for Koolermax RO syste
2 x 350UP, Upgrade Kit TFC50 gal/day (includes US membrane filter)
1 x Optional: 564 Membrane Filter Housing Wrench Opener
1 x FK-BB10K3, Big Blue Filter Pack Bundle for WH-1030 Whole House
2 x 532b, PAE RO Water Storage Pressure Osmosis Tank Container 4G
1 x 1.SED2005, 1st stage sediment filter 20" inch for RD322 RO260
1 x 701, FH1014 Filter Housing Chamber Casing White Color 1/4 FPT
1 x 752set, DC Booster Pump Transformer Solenoid Pressure Switch All
1 x Special, Output Conversion Kit Convert from 1/4" to 3/8"
1 x TMR-AQT-68, Transformer Power Supply Aquatec TACS114-19EP for 68
1 x 581, Ice Maker Hookup Kit Connect RO water to Fridge Ice Maker
1 x 741-38, Diverter Valve for RO DI Water Systems
1 x SVkit, Pump Shutoff Switch Kit for Aquatec Booster Pumps ESO TSO
1 x 215, 5th or 6th Stage Refillable inline DI filter (color change)
1 x KF310UP, SUBSTITUTE/Upgrade to KYTON FAUCET POLISHED CHROME FINI
2 x PSW-240 Aquatec Pressure Switch 40 psi shut off 1/4" tubing TSO
1 x Wrench 2 pcs 566 Standard Filter Housing Opener Double Better
2 x 205, 3rd stage solid carbon block filter (replace every 12month)
1 x SC227, Specialty Filter Refillable Color Changing DI Filter 20"
1 x 201, 1st stage sediment filter (replace every 6-12 months)
1 x FK-53, Replacement Filter Pack SED2005 CB2010 for RD322 RO260
1 x 532bpg, PAE RO water pressure tank blue bladder gauge valve 4G
1 x B2012, 20" Long Slim Filter Cartridge Housing RO260 RD322
1 x 3150, 5th stage TFC-150 US membrane filter (every 2-3 years)
1 x 4th stage TFC150 US membrane filter (every 2-3 yrs)M150 P/N3150
1 x 818, DI Resin Refill Bag 16oz (good for up to three refills)
1 x OPTIONAL: 567 Filter Housing Wrench Case Opener WHOLE HOUSE WH
1 x 3rd stage C10 carbon block filter (replace every 6-12 months)
1 x PSW-280 Aquatec Pressure Switch 80 psi shut off 1/4 tubing TSO
1 x B1034, 10" Big Blue Filter Housing Cartridge WH5 WH10 WH1134
1 x SET8855 Aquatec 5853 Booster Pump Assembly for Aeroponics System
1 x SC412, Water Softening Filter Calcium Magnesium Hardness Removal

View Cart$1,536.49
Specials Log InCreate Account Checkout  Shopping Cart42 item(s)
1 x 4042-K Male Elbow Fitting Compression type(membrane housing use)
2 x 752, DC Booster Pump w/ Transformer
1 x 709, Automatic Shut Off Valve 4-way Four Way Valve
1 x 531, PAE RO Storage Pressure Osmosis Water Tank Container 3G
1 x 1st stage SF05 sediment filter (replace every 6-12 months)
1 x 733, Built-in Pressure Gauge 0 to 150 psi for Koolermax RO syste
2 x 350UP, Upgrade Kit TFC50 gal/day (includes US membrane filter)
1 x Optional: 564 Membrane Filter Housing Wrench Opener
1 x FK-BB10K3, Big Blue Filter Pack Bundle for WH-1030 Whole House
2 x 532b, PAE RO Water Storage Pressure Osmosis Tank Container 4G
1 x 1.SED2005, 1st stage sediment filter 20" inch for RD322 RO260
1 x 701, FH1014 Filter Housing Chamber Casing White Color 1/4 FPT
1 x 752set, DC Booster Pump Transformer Solenoid Pressure Switch All
1 x Special, Output Conversion Kit Convert from 1/4" to 3/8"
1 x TMR-AQT-68, Transformer Power Supply Aquatec TACS114-19EP for 68
1 x 581, Ice Maker Hookup Kit Connect RO water to Fridge Ice Maker
1 x 741-38, Diverter Valve for RO DI Water Systems
1 x SVkit, Pump Shutoff Switch Kit for Aquatec Booster Pumps ESO TSO
1 x 215, 5th or 6th Stage Refillable inline DI filter (color change)
1 x KF310UP, SUBSTITUTE/Upgrade to KYTON FAUCET POLISHED CHROME FINI
2 x PSW-240 Aquatec Pressure Switch 40 psi shut off 1/4" tubing TSO
1 x Wrench 2 pcs 566 Standard Filter Housing Opener Double Better
2 x 205, 3rd stage solid carbon block filter (replace every 12month)
1 x SC227, Specialty Filter Refillable Color Changing DI Filter 20"
1 x 201, 1st stage sediment filter (replace every 6-12 months)
1 x FK-53, Replacement Filter Pack SED2005 CB2010 for RD322 RO260
1 x 532bpg, PAE RO water pressure tank blue bladder gauge valve 4G
1 x B2012, 20" Long Slim Filter Cartridge Housing RO260 RD322
1 x 3150, 5th stage TFC-150 US membrane filter (every 2-3 years)
1 x 4th stage TFC150 US membrane filter (every 2-3 yrs)M150 P/N3150
1 x 818, DI Resin Refill Bag 16oz (good for up to three refills)
1 x OPTIONAL: 567 Filter Housing Wrench Case Opener WHOLE HOUSE WH
1 x 3rd stage C10 carbon block filter (replace every 6-12 months)
1 x PSW-280 Aquatec Pressure Switch 80 psi shut off 1/4 tubing TSO
1 x B1034, 10" Big Blue Filter Housing Cartridge WH5 WH10 WH1134
1 x SET8855 Aquatec 5853 Booster Pump Assembly for Aeroponics System
1 x SC412, Water Softening Filter Calcium Magnesium Hardness Removal

View Cart$1,536.49

*Discontinued* RO585 [RO-585]

$159.00

*Discontinued* RO585



* RO-585 5-stage 85 gal/day Reverse osmosis RO system

This system is a complete system ready to be installed.  It includes all filters, storage tank (4gal. tank), faucet, tubing, installation hardware, installation manual.  All filters and membrane are standard size.

1st stage:  high capacity, 5 micron sediment filter, to remove sediment, rust, sand, (replace every 12 months)

2nd stage:  high capacity carbon filter, coconut shell carbon block filter removes chlorine, taste & odor (replace every 12 months)

3rd stage:  high capacity carbon filter, coconut shell carbon block filter further removing chlorine to ensure 100% removal of chlorine (replace every 12 months)

4th stage:  TFC-75 Premium membrane we use genuine US MEMBRANE membrane filter, 75-85 gal/day, it removes 97% to 98% of all chemical, dissolved solids in tap water. (replace every 2-3 years)

5th stage:  high capacity final stage inline carbon filter, granular activated carbon, to improve taste of water. (replace every 12 months)

System Dimension: RO unit: 15" length, 16" height, 5.5" depth ; Storage tank: 10.5" diameter, 15" height

FREE bonus Pressure Gauge:  It's helpful in monitoring:

  1. House water pressure
  2. Operating pressure of the RO system
  3. When to replace sediment & carbon filters
  4. When troubleshooting the system

RO Storage Tank:  4 gallon tank, holding 3 to 3.2 gallons of water depending on water pressure, NSF listed tank, stainless steel connector, FDA approved butyl rubber water bladder, pre-charged with compressed air, (no additional charging or adjustment is necessary). Dimension: 10.5" diameter x 15" tall
Automatic-Shut-Off Valve is included, when storage tank is full, the system shuts off to prevent wastage of water going to the drain.

Feed Water Adapter: for under the sink installation, we give you the adapter with valve to put in between the cold water line. Our adapter has several advantages over the self-piercing valve.  Our adapter will not clog up like the needle point piercing valve.  Also our adapter does not require putting a hole in the pipe.  You can easily replace the valve or relocate the valve without changing your piping, unlike the other self-piercing valve, where once it punctures a hole you cannot replace the valve, then you need to replace the pipe and the valve.

 

Flow restrictor:

We use a fixed rate flow restrictor to accurately restrict the drain line and create proper working pressure for the operation of the reverse osmosis process.  Therefore, a more efficient and favorable pure water to drain ratio is achieved at 1:3

 

NOTE:  We have abandoned the type of flow restrictor that has a black lever on top for flushing since it is not an accurate flow restrictor.

Optional Manual flush valve:

The system flushes itself when it is making water.  In most cases a manual flush valve is not required.  However, it is beneficial to manually flush the membrane if the water supply is from well or very hard water, above 600 ppm of TDS or Hardness.  Optional manual flush valve requires additional fee.

Standard Long Reach Faucet:  chrome

a 5/8" or 1/2" hole or larger hole is required on the countertop

** Important Note: All reverse osmosis systems, residential or commercial, are required to have drain water when making pure water. Our RO systems have built-in auto-shut-off valve so when the storage tank is full, the system shuts off automatically. The ratio of pure water to drain water for our RO systems are 1:3 (calculated). Average RO systems are typically 1:4, so our RO systems run more efficiently. Minimum water pressure required to operate the system is 45 PSI. Ideal pressure is 85 PSI.

Reviews (10)

 Customers who bought this product also purchased

Home  |   Specials  |   Log In  |   Create Account  |   Checkout  |   Shopping Cart