2 x 3150, 4th stage TFC-150 US membrane filter (every 2-3 yrs)
1 x HK120-P-TK-220V for EURO 220V / 50Hz
2 x 335UP, Upgrade Kit TFC 35 gal/day (includes US membrane filter)
2 x CPR-150G, Pressure Regulator with Pressure Gauge (0-125 psi)
1 x 745, AFAN0409 Female Garden Hose / Laundry Hose Adapter
1 x 2nd stage C10 carbon block filter (replace every 6-12 months)
1 x B2010, 20" Big Blue Filter Housing Cartridge WH20 WH25 WH250
1 x 201, 1st stage sediment filter (replace every 6-12 months)
2 x PSW-350, Pressure Switch for RO Booster Pump 1/4" TSO
1 x CBV-0404, Tank Ball Valve to 1/4 tubing *standard RO tank size*
1 x Wrench 2 pcs 566 Standard Filter Housing Opener Double Better
1 x CKV0402, Blue color Elbow Check Valve Elbow Type
1 x MK800, Maintenance kit for AR122, AR125, HK120, RD150, RO155
1 x 225UP, 5th stage Inline Alkaline upgrade (includes media)
1 x WH-10, Whole House Water Treatment Carbon Filter System 10" Big
1 x SC435, Specialty Filter Arsenic / Fluoride Removal Filter
1 x .RD322 Aquarium 260-300 GPD REVERSE OSMOSIS RO+DI WATER SYSTEM
1 x 720, Feed Water Adapter with Needle Valve
1 x FPK, 6 pcs Fitting Pack Union Connector 1/4" quarter inch
1 x 2.CB2010, 2nd stage carbon block filter 20" inch for RD322 RO260
1 x *Discontinued* RD106
1 x TMR-AQT-68, Transformer Power Supply Aquatec TACS114-19EP for 68
1 x 6044-K Tee Fitting Compression Type 1/4"OD 1/4" NPT
1 x 6th Stage pn215 Refillable inline DI filter (color change)
1 x FPK, 6 pcs Fitting Pack Union Connector 1/2 x 3/8 inch
1 x KF750UP, SUBSTITUTE/Upgrade KOOLERMAX Faucet CHROME FINISH
1 x OPTIONAL: 567 Filter Housing Wrench Case Opener WHOLE HOUSE WH
1 x 706, Membrane Filter Casing Housing Assembly
1 x 721, Self-Piercing Valve, Feed Water Adapter for Copper Pipe
1 x 741-14, Diverter Valve for Countertop Water Units
1 x HK120-P-TK for USA 110V / 60Hz
1 x BUNDLE PACK Annual Filter Kit FK4 WaterGeneral 585 106 (4 ITEMS)
1 x 290, CB2010BB Big Blue 20" Carbon Block Filter WH20 WH250 WH2201
1 x RF62, Replacement filter for CT-6000, UC7000, SW-1, and SW-1C
1 x 285, Big Blue SED2005BB 20" Sediment filter WH25 WH250 WH2201
1 x KF612, Elite Series: Oil Rubbed Bronze ORB Drinking Water Faucet
1 x KM701, Special Koolermax Filter Housing Canister Casing 1/4 FPT
1 x B2012, 20" Long Slim Filter Cartridge Housing RO260 RD322
1 x 5th stage 225 Inline Alkaline filter with clear housing (annual)

View Cart$2,220.15
Specials Log InCreate Account Checkout  Shopping Cart43 item(s)
2 x 3150, 4th stage TFC-150 US membrane filter (every 2-3 yrs)
1 x HK120-P-TK-220V for EURO 220V / 50Hz
2 x 335UP, Upgrade Kit TFC 35 gal/day (includes US membrane filter)
2 x CPR-150G, Pressure Regulator with Pressure Gauge (0-125 psi)
1 x 745, AFAN0409 Female Garden Hose / Laundry Hose Adapter
1 x 2nd stage C10 carbon block filter (replace every 6-12 months)
1 x B2010, 20" Big Blue Filter Housing Cartridge WH20 WH25 WH250
1 x 201, 1st stage sediment filter (replace every 6-12 months)
2 x PSW-350, Pressure Switch for RO Booster Pump 1/4" TSO
1 x CBV-0404, Tank Ball Valve to 1/4 tubing *standard RO tank size*
1 x Wrench 2 pcs 566 Standard Filter Housing Opener Double Better
1 x CKV0402, Blue color Elbow Check Valve Elbow Type
1 x MK800, Maintenance kit for AR122, AR125, HK120, RD150, RO155
1 x 225UP, 5th stage Inline Alkaline upgrade (includes media)
1 x WH-10, Whole House Water Treatment Carbon Filter System 10" Big
1 x SC435, Specialty Filter Arsenic / Fluoride Removal Filter
1 x .RD322 Aquarium 260-300 GPD REVERSE OSMOSIS RO+DI WATER SYSTEM
1 x 720, Feed Water Adapter with Needle Valve
1 x FPK, 6 pcs Fitting Pack Union Connector 1/4" quarter inch
1 x 2.CB2010, 2nd stage carbon block filter 20" inch for RD322 RO260
1 x *Discontinued* RD106
1 x TMR-AQT-68, Transformer Power Supply Aquatec TACS114-19EP for 68
1 x 6044-K Tee Fitting Compression Type 1/4"OD 1/4" NPT
1 x 6th Stage pn215 Refillable inline DI filter (color change)
1 x FPK, 6 pcs Fitting Pack Union Connector 1/2 x 3/8 inch
1 x KF750UP, SUBSTITUTE/Upgrade KOOLERMAX Faucet CHROME FINISH
1 x OPTIONAL: 567 Filter Housing Wrench Case Opener WHOLE HOUSE WH
1 x 706, Membrane Filter Casing Housing Assembly
1 x 721, Self-Piercing Valve, Feed Water Adapter for Copper Pipe
1 x 741-14, Diverter Valve for Countertop Water Units
1 x HK120-P-TK for USA 110V / 60Hz
1 x BUNDLE PACK Annual Filter Kit FK4 WaterGeneral 585 106 (4 ITEMS)
1 x 290, CB2010BB Big Blue 20" Carbon Block Filter WH20 WH250 WH2201
1 x RF62, Replacement filter for CT-6000, UC7000, SW-1, and SW-1C
1 x 285, Big Blue SED2005BB 20" Sediment filter WH25 WH250 WH2201
1 x KF612, Elite Series: Oil Rubbed Bronze ORB Drinking Water Faucet
1 x KM701, Special Koolermax Filter Housing Canister Casing 1/4 FPT
1 x B2012, 20" Long Slim Filter Cartridge Housing RO260 RD322
1 x 5th stage 225 Inline Alkaline filter with clear housing (annual)

View Cart$2,220.15

*Discontinued* RO585 [RO-585]

$159.00

*Discontinued* RO585



* RO-585 5-stage 85 gal/day Reverse osmosis RO system

This system is a complete system ready to be installed.  It includes all filters, storage tank (4gal. tank), faucet, tubing, installation hardware, installation manual.  All filters and membrane are standard size.

1st stage:  high capacity, 5 micron sediment filter, to remove sediment, rust, sand, (replace every 12 months)

2nd stage:  high capacity carbon filter, coconut shell carbon block filter removes chlorine, taste & odor (replace every 12 months)

3rd stage:  high capacity carbon filter, coconut shell carbon block filter further removing chlorine to ensure 100% removal of chlorine (replace every 12 months)

4th stage:  TFC-75 Premium membrane we use genuine US MEMBRANE membrane filter, 75-85 gal/day, it removes 97% to 98% of all chemical, dissolved solids in tap water. (replace every 2-3 years)

5th stage:  high capacity final stage inline carbon filter, granular activated carbon, to improve taste of water. (replace every 12 months)

System Dimension: RO unit: 15" length, 16" height, 5.5" depth ; Storage tank: 10.5" diameter, 15" height

FREE bonus Pressure Gauge:  It's helpful in monitoring:

  1. House water pressure
  2. Operating pressure of the RO system
  3. When to replace sediment & carbon filters
  4. When troubleshooting the system

RO Storage Tank:  4 gallon tank, holding 3 to 3.2 gallons of water depending on water pressure, NSF listed tank, stainless steel connector, FDA approved butyl rubber water bladder, pre-charged with compressed air, (no additional charging or adjustment is necessary). Dimension: 10.5" diameter x 15" tall
Automatic-Shut-Off Valve is included, when storage tank is full, the system shuts off to prevent wastage of water going to the drain.

Feed Water Adapter: for under the sink installation, we give you the adapter with valve to put in between the cold water line. Our adapter has several advantages over the self-piercing valve.  Our adapter will not clog up like the needle point piercing valve.  Also our adapter does not require putting a hole in the pipe.  You can easily replace the valve or relocate the valve without changing your piping, unlike the other self-piercing valve, where once it punctures a hole you cannot replace the valve, then you need to replace the pipe and the valve.

 

Flow restrictor:

We use a fixed rate flow restrictor to accurately restrict the drain line and create proper working pressure for the operation of the reverse osmosis process.  Therefore, a more efficient and favorable pure water to drain ratio is achieved at 1:3

 

NOTE:  We have abandoned the type of flow restrictor that has a black lever on top for flushing since it is not an accurate flow restrictor.

Optional Manual flush valve:

The system flushes itself when it is making water.  In most cases a manual flush valve is not required.  However, it is beneficial to manually flush the membrane if the water supply is from well or very hard water, above 600 ppm of TDS or Hardness.  Optional manual flush valve requires additional fee.

Standard Long Reach Faucet:  chrome

a 5/8" or 1/2" hole or larger hole is required on the countertop

** Important Note: All reverse osmosis systems, residential or commercial, are required to have drain water when making pure water. Our RO systems have built-in auto-shut-off valve so when the storage tank is full, the system shuts off automatically. The ratio of pure water to drain water for our RO systems are 1:3 (calculated). Average RO systems are typically 1:4, so our RO systems run more efficiently. Minimum water pressure required to operate the system is 45 PSI. Ideal pressure is 85 PSI.