Log In Log In  |  Checkout   |  54 item(s)
1 x *Discontinued* RO585A
1 x 205, 3rd stage solid carbon block filter (replace every 12month)
1 x 1/2" NPT Digiflow Digital Flow Meter count up total Water Gallon
1 x 215, 5th or 6th Stage Refillable inline DI filter (color change)
1 x .K6A KoolerMax 75GPD 6STAGE Alkaline pH REVERSE OSMOSIS RO FILTE
1 x *Discontinued* RD106
1 x FM214G 1/4" NPT Digital Flow Meter count up total Water Gallons
1 x 531, PAE RO Storage Pressure Osmosis Water Tank Container 3G
1 x NM-5104, HONEYWELL COUNTERTOP WATER FILTER *DISCONTINUED* SW1
1 x .AR125NTF KoolerMax AR125 RO System Shell without tank & faucet
1 x 818, DI Resin Refill Bag 16oz (good for up to three refills)
1 x 215, 5th or 6th Stage Refillable inline DI filter (color change)
1 x FM-8100T, DigiFlow Digital Water Flow Rate Meter 56" cable
1 x 350UP, Upgrade Kit TFC50 gal/day (includes US membrane filter)
1 x FM-8000T, DigiFlow Digital Water Flow Meter Rate Count Down
1 x .K5NTF KoolerMax K5 RO System Shell without tank and faucet
1 x CP-OR35+701 O-RING FOR WATERGENERAL BOTTOM FILTER HOUSING CASING
1 x 565, Digital Pressure Gauge Tester Monitor
1 x 318, 4th stage TFC-18 US membrane filter (replace every 2-3 yrs)
1 x FM-6710M-88 1" Digital Flow Meter count up Total GPM 56" cable
1 x 277, SED1005BB Big Blue 5 micron sediment filter 10"
1 x Optional: 566 Filter Housing Wrench Opener WaterGeneral System
1 x 201, 1st stage sediment filter (replace every 6-12 months)
1 x KF355UP, SUBSTITUTE/Upgrade to Antique Brushed Brass Iron Finish
1 x MK225, Maintenance kit for Honeywell RO9100 Filtercold RO5 AV180
1 x IM60, Ice Maker or RV Water Filter, Inline Typle
1 x KT-103, Optional Manual Membrane Flush Valve
1 x 578, TDS Water Quality Meter tds-3
1 x 1070, PAE LARGE RO Storage Pressure Tank 14 GALLON 14G
1 x FM-8100TG44, DigiFlow Digital Water Flow Rate Meter
1 x KF511UP SUBSTITUTE/Upgrade Faucet CHROME GOLD TRIM CROSS HANDLE
1 x AQF-600-105, Flow Meter Panel Mount 1/2" MPT
1 x 3150, 4th stage TFC-150 US membrane filter (every 2-3 yrs)
1 x FM214G, FM-6710M DigiFlow Digital Water Flow Meter Gauge Moniter
1 x 733, Built-in Pressure Gauge 0 to 150 psi for Koolermax RO syste
1 x 213, 5th stage inline carbon postfilter (replace every 12months)
1 x DM-2, Inline Dual TDS monitor (meter) for RO DI System DM2
1 x Panel 1/4 Digital Flow Meter count up total Gallons GPM 56"cable
1 x Panel 1/2" 6710M-44TM Digital Flow Meter count up Gallon 115V
1 x 532b, PAE RO Water Storage Pressure Osmosis Tank Container 4G
1 x Value Pack- Entire 3 Years of Replacement Filters Bundle RD150
1 x KF750UP, SUBSTITUTE/Upgrade KOOLERMAX Faucet CHROME FINISH
1 x CPR-150G, Pressure Regulator with Pressure Gauge (0-125 psi)
1 x .K5 KoolerMax 75GPD 5 STAGE REVERSE OSMOSIS RO FILTER SYSTEM
1 x Micro 1/4 NPT Digital Flow Meter count up total Water Liter LPM
1 x .AR125 Dual Outputs Aquarium & Home Drinking RO Filter System
2 x 532w, PAE RO Storage Pressure Osmosis Water Tank Container 4G
1 x 701, FH1014 Filter Housing Chamber Casing White Color 1/4 FPT
1 x 532bpg, PAE RO water pressure tank blue bladder gauge valve 4G
1 x .K6NTF KoolerMax K6ALK RO shell without tank and faucet
1 x *Discontinued* RO585
1 x RF62, Replacement filter for CT-6000, UC7000, SW-1, and SW-1C
1 x Panel 3/4" 6710M-66TM Digital Flow Meter count up GPM 115V

View Cart$3,254.50
Specials Log InCreate Account Checkout  Shopping Cart54 item(s)
1 x *Discontinued* RO585A
1 x 205, 3rd stage solid carbon block filter (replace every 12month)
1 x 1/2" NPT Digiflow Digital Flow Meter count up total Water Gallon
1 x 215, 5th or 6th Stage Refillable inline DI filter (color change)
1 x .K6A KoolerMax 75GPD 6STAGE Alkaline pH REVERSE OSMOSIS RO FILTE
1 x *Discontinued* RD106
1 x FM214G 1/4" NPT Digital Flow Meter count up total Water Gallons
1 x 531, PAE RO Storage Pressure Osmosis Water Tank Container 3G
1 x NM-5104, HONEYWELL COUNTERTOP WATER FILTER *DISCONTINUED* SW1
1 x .AR125NTF KoolerMax AR125 RO System Shell without tank & faucet
1 x 818, DI Resin Refill Bag 16oz (good for up to three refills)
1 x 215, 5th or 6th Stage Refillable inline DI filter (color change)
1 x FM-8100T, DigiFlow Digital Water Flow Rate Meter 56" cable
1 x 350UP, Upgrade Kit TFC50 gal/day (includes US membrane filter)
1 x FM-8000T, DigiFlow Digital Water Flow Meter Rate Count Down
1 x .K5NTF KoolerMax K5 RO System Shell without tank and faucet
1 x CP-OR35+701 O-RING FOR WATERGENERAL BOTTOM FILTER HOUSING CASING
1 x 565, Digital Pressure Gauge Tester Monitor
1 x 318, 4th stage TFC-18 US membrane filter (replace every 2-3 yrs)
1 x FM-6710M-88 1" Digital Flow Meter count up Total GPM 56" cable
1 x 277, SED1005BB Big Blue 5 micron sediment filter 10"
1 x Optional: 566 Filter Housing Wrench Opener WaterGeneral System
1 x 201, 1st stage sediment filter (replace every 6-12 months)
1 x KF355UP, SUBSTITUTE/Upgrade to Antique Brushed Brass Iron Finish
1 x MK225, Maintenance kit for Honeywell RO9100 Filtercold RO5 AV180
1 x IM60, Ice Maker or RV Water Filter, Inline Typle
1 x KT-103, Optional Manual Membrane Flush Valve
1 x 578, TDS Water Quality Meter tds-3
1 x 1070, PAE LARGE RO Storage Pressure Tank 14 GALLON 14G
1 x FM-8100TG44, DigiFlow Digital Water Flow Rate Meter
1 x KF511UP SUBSTITUTE/Upgrade Faucet CHROME GOLD TRIM CROSS HANDLE
1 x AQF-600-105, Flow Meter Panel Mount 1/2" MPT
1 x 3150, 4th stage TFC-150 US membrane filter (every 2-3 yrs)
1 x FM214G, FM-6710M DigiFlow Digital Water Flow Meter Gauge Moniter
1 x 733, Built-in Pressure Gauge 0 to 150 psi for Koolermax RO syste
1 x 213, 5th stage inline carbon postfilter (replace every 12months)
1 x DM-2, Inline Dual TDS monitor (meter) for RO DI System DM2
1 x Panel 1/4 Digital Flow Meter count up total Gallons GPM 56"cable
1 x Panel 1/2" 6710M-44TM Digital Flow Meter count up Gallon 115V
1 x 532b, PAE RO Water Storage Pressure Osmosis Tank Container 4G
1 x Value Pack- Entire 3 Years of Replacement Filters Bundle RD150
1 x KF750UP, SUBSTITUTE/Upgrade KOOLERMAX Faucet CHROME FINISH
1 x CPR-150G, Pressure Regulator with Pressure Gauge (0-125 psi)
1 x .K5 KoolerMax 75GPD 5 STAGE REVERSE OSMOSIS RO FILTER SYSTEM
1 x Micro 1/4 NPT Digital Flow Meter count up total Water Liter LPM
1 x .AR125 Dual Outputs Aquarium & Home Drinking RO Filter System
2 x 532w, PAE RO Storage Pressure Osmosis Water Tank Container 4G
1 x 701, FH1014 Filter Housing Chamber Casing White Color 1/4 FPT
1 x 532bpg, PAE RO water pressure tank blue bladder gauge valve 4G
1 x .K6NTF KoolerMax K6ALK RO shell without tank and faucet
1 x *Discontinued* RO585
1 x RF62, Replacement filter for CT-6000, UC7000, SW-1, and SW-1C
1 x Panel 3/4" 6710M-66TM Digital Flow Meter count up GPM 115V

View Cart$3,254.50

318, 4th stage TFC-18 US membrane filter (replace every 2-3 yrs) [318]

$52.00

318, 4th stage TFC-18 US membrane filter (replace every 2-3 yrs)

p/n 318 will be automatically upgraded to 24GPD membrane with no charge.

Brand Name: US Membrane

Assembled and made in California, USA

Standard size Reverse Osmosis membrane filter.  Fits all standard size RO systems and membrane housing.

 

Model#  TFC-24  24GPD gallons per day capacity

Part/No  324

 

Specifications:

 

This membrane fits all standard size membrane housing, standard RO systems. 

You can increase the capacity of your existing RO system by getting a higher capacity membrane filter with a matching flow restrictor, or getting a membrane module which comes with membrane filter, housing, fitting, flow restrictor, and check valve.

 

Membrane Material:  TFC Thin Film Composite

Production rate: 24 gallons per day max.  Actual production rate varies depending on input pressure and temperature.

Max. Operating Pressure:  130 psi

Max. Operating Temperature:  120 F  ( 49 C)

Recommended concentrate flow rate: 3x permeate (drain to pure water ratio  3:1)

pH range: 3- 11

Chlorine Tolerance: 0 ppm

Dimension:  standard size 2” diameter x 11.75” length

 

Performance:

Applied water supply pressure: 65 psi at 77F

Nominal Salt rejection rate: 98%

Nominal TDS rejection rate: about 95%  at 300 ppm input

 

Features:

Consistent quality and reliability using automated production line.

Dry type membrane for extended shelf life

Fits all standard membrane housings

 

 

How to choose the correct RO membrane filter for your RO system?

  1.  You need to have a standard size RO system with standard membrane housing (look at photo)
  2. Check the capacity of your RO system or RO membrane.  Capacity means how fast the membrane produces water.  The number means gallons per day (GPD).  You can find this from your RO system owner’s manual, and specifications.
  3. You can also find the GPD rating from the membrane filter label when you take out the membrane filter.
  4. You can also find the GPD rating from the drain flow rate or from the flow restrictor that is connected to the drain line.

Flow restrictor size (drain rate) 200 mL/min. uses TFC-24 membrane

Flow restrictor size (drain rate) 300 mL/min. uses TFC-36 membrane

Flow restrictor size (drain rate) 420 mL/min. uses TFC-50 membrane

Flow restrictor size (drain rate) 500 mL/min. uses TFC-75 membrane

Flow restrictor size (drain rate) 500 to 600 mL/min. uses TFC-100 membrane

Flow restrictor size (drain rate) 800 to 850 mL/min. uses TFC-150 membrane

Reviews (1)

 Customers who bought this product also purchased

Home  |   Specials  |   Log In  |   Create Account  |   Checkout  |   Shopping Cart