Log In Log In  |  Checkout   |  25 item(s)
1 x bulk213, Inline Carbon Filter
1 x TMR-UV-6W, Replacement UV Ballast Transformer 6 Watts for 602 UV
1 x N-14-1M, Nipple Fitting connector between standard RO housing
1 x bulkc10, Koolermax Carbon Block Filter
1 x Wrench 2 pcs 566 Standard Filter Housing Opener Double Better
1 x SV-24DC-14, Solenoid Valve ESO 1/4" plastic, 24V DC
1 x SV-24DC-38-Plastic, KSD Solenoid Valve 3/8" 24V DC ESO
1 x PSW-3100 Aquatec Pressure Switch 100 psi shut off 3/8 tubing TSO
1 x UC SHELL, Honeywell UC7000 Empty System Only No Filter
1 x TMR-AQT-68, Transformer Power Supply Aquatec TACS114-19EP for 68
1 x bulksf05, Koolermax Sediment Filter
1 x UU Clips Pair Membrane to Membrane, 2.5" to 2.5"
1 x Y3414BR, Garden Hose Y Adapter Shutoff Valve Brass Construction
1 x Optional: 566 Filter Housing Wrench Opener WaterGeneral System
1 x PSW-240 Aquatec Pressure Switch 40 psi shut off 1/4" tubing TSO
1 x bulkic21, Koolermax Inline Carbon Filter
1 x MK550, Maintenance kit for RO585, RD102, RD106, RO6, K5, K6
1 x UU Clips Pair Membrane to Filter, 2.5" to 2"
1 x TMR-DC-1212, Transformer Power Supply for Delivery Demand Pump
1 x SV-110AC-14, Solenoid Valve 1/4" plastic 110VAC ESO
1 x OPTIONAL: 567 Filter Housing Wrench Case Opener WHOLE HOUSE WH
1 x TMR-25A, 2.5 AMP Transformer Power Supply Ballast for 8800 5853
1 x TMR-220V-1A Aquatec TACS234-19 Transformer Power Supply EuroPlug
1 x PSW-280 Aquatec Pressure Switch 80 psi shut off 1/4 tubing TSO
1 x TMR-AQT-2A, Transformer Power Supply Aquatec TACS114-48 for 8800

View Cart$1,218.00
Specials Log InCreate Account Checkout  Shopping Cart25 item(s)
1 x bulk213, Inline Carbon Filter
1 x TMR-UV-6W, Replacement UV Ballast Transformer 6 Watts for 602 UV
1 x N-14-1M, Nipple Fitting connector between standard RO housing
1 x bulkc10, Koolermax Carbon Block Filter
1 x Wrench 2 pcs 566 Standard Filter Housing Opener Double Better
1 x SV-24DC-14, Solenoid Valve ESO 1/4" plastic, 24V DC
1 x SV-24DC-38-Plastic, KSD Solenoid Valve 3/8" 24V DC ESO
1 x PSW-3100 Aquatec Pressure Switch 100 psi shut off 3/8 tubing TSO
1 x UC SHELL, Honeywell UC7000 Empty System Only No Filter
1 x TMR-AQT-68, Transformer Power Supply Aquatec TACS114-19EP for 68
1 x bulksf05, Koolermax Sediment Filter
1 x UU Clips Pair Membrane to Membrane, 2.5" to 2.5"
1 x Y3414BR, Garden Hose Y Adapter Shutoff Valve Brass Construction
1 x Optional: 566 Filter Housing Wrench Opener WaterGeneral System
1 x PSW-240 Aquatec Pressure Switch 40 psi shut off 1/4" tubing TSO
1 x bulkic21, Koolermax Inline Carbon Filter
1 x MK550, Maintenance kit for RO585, RD102, RD106, RO6, K5, K6
1 x UU Clips Pair Membrane to Filter, 2.5" to 2"
1 x TMR-DC-1212, Transformer Power Supply for Delivery Demand Pump
1 x SV-110AC-14, Solenoid Valve 1/4" plastic 110VAC ESO
1 x OPTIONAL: 567 Filter Housing Wrench Case Opener WHOLE HOUSE WH
1 x TMR-25A, 2.5 AMP Transformer Power Supply Ballast for 8800 5853
1 x TMR-220V-1A Aquatec TACS234-19 Transformer Power Supply EuroPlug
1 x PSW-280 Aquatec Pressure Switch 80 psi shut off 1/4 tubing TSO
1 x TMR-AQT-2A, Transformer Power Supply Aquatec TACS114-48 for 8800

View Cart$1,218.00

318, 4th stage TFC-18 US membrane filter (replace every 2-3 yrs) [318]

$52.00

318, 4th stage TFC-18 US membrane filter (replace every 2-3 yrs)

p/n 318 will be automatically upgraded to 24GPD membrane with no charge.

Brand Name: US Membrane

Assembled and made in California, USA

Standard size Reverse Osmosis membrane filter.  Fits all standard size RO systems and membrane housing.

 

Model#  TFC-24  24GPD gallons per day capacity

Part/No  324

 

Specifications:

 

This membrane fits all standard size membrane housing, standard RO systems. 

You can increase the capacity of your existing RO system by getting a higher capacity membrane filter with a matching flow restrictor, or getting a membrane module which comes with membrane filter, housing, fitting, flow restrictor, and check valve.

 

Membrane Material:  TFC Thin Film Composite

Production rate: 24 gallons per day max.  Actual production rate varies depending on input pressure and temperature.

Max. Operating Pressure:  130 psi

Max. Operating Temperature:  120 F  ( 49 C)

Recommended concentrate flow rate: 3x permeate (drain to pure water ratio  3:1)

pH range: 3- 11

Chlorine Tolerance: 0 ppm

Dimension:  standard size 2” diameter x 11.75” length

 

Performance:

Applied water supply pressure: 65 psi at 77F

Nominal Salt rejection rate: 98%

Nominal TDS rejection rate: about 95%  at 300 ppm input

 

Features:

Consistent quality and reliability using automated production line.

Dry type membrane for extended shelf life

Fits all standard membrane housings

 

 

How to choose the correct RO membrane filter for your RO system?

  1.  You need to have a standard size RO system with standard membrane housing (look at photo)
  2. Check the capacity of your RO system or RO membrane.  Capacity means how fast the membrane produces water.  The number means gallons per day (GPD).  You can find this from your RO system owner’s manual, and specifications.
  3. You can also find the GPD rating from the membrane filter label when you take out the membrane filter.
  4. You can also find the GPD rating from the drain flow rate or from the flow restrictor that is connected to the drain line.

Flow restrictor size (drain rate) 200 mL/min. uses TFC-24 membrane

Flow restrictor size (drain rate) 300 mL/min. uses TFC-36 membrane

Flow restrictor size (drain rate) 420 mL/min. uses TFC-50 membrane

Flow restrictor size (drain rate) 500 mL/min. uses TFC-75 membrane

Flow restrictor size (drain rate) 500 to 600 mL/min. uses TFC-100 membrane

Flow restrictor size (drain rate) 800 to 850 mL/min. uses TFC-150 membrane

Reviews (1)

 Customers who bought this product also purchased

Home  |   Specials  |   Log In  |   Create Account  |   Checkout  |   Shopping Cart