Log In Log In  |  Checkout   |  106 item(s)
1 x 5th or 6th Stage IC21 inline carbon filter (every 6 to 12 mons)
1 x MKP, Maintenance kit for K5150P K6150P AR150P
2 x 719, Drain Saddle Clamp / Valve
1 x ERP500 Aquatec Permeate Pump Reverse Osmosis RO System USA made
1 x 225, 5th stage Inline Alkaline filter with clear case (annual)
1 x 213, 5th or 6th stage inline carbon filter (replace in 12 mons)
1 x SVkit, Pump Shutoff Switch Kit for Aquatec Booster Pumps ESO TSO
2 x KM701, Special Koolermax Filter Housing Canister Casing 1/4 FPT
1 x SV-24AC-38, KSD Solenoid Valve ESO 3/8" brass, 24V AC
1 x *Discontinued* RO585ERP
3 x 205, 3rd stage solid carbon block filter (replace every 12month)
1 x WH-5, Whole House Water Treatment Sediment Filter System 10" Big
2 x 532wpg, PAE RO water pressure white tank bladder gauge valve 4G
1 x Annual Filter Kit Koolermax Series KPAK-3 Sediment Carbon Block
1 x 4th stage TFC150 US membrane filter (every 2-3 yrs)M150 P/N3150
1 x FM-8100T, DigiFlow Digital Water Flow Rate Meter 56" cable
2 x 4044-K Male Elbow Fitting Compression type 1/4" OD 1/4" NPT
1 x AQUATEC 8852-2J03-B424 High Flow Booster Pump 110V Transformer
1 x Optional: 566 Filter Housing Wrench Opener WaterGeneral System
1 x B2010, 20" Big Blue Filter Housing Cartridge WH20 WH25 WH250
1 x SV-24AC-14, Solenoid Valve ESO for Aquatec pump 1/4" wiring
1 x B1034, 10" Big Blue Filter Housing Cartridge WH5 WH10 WH1134
1 x O-RING FOR WH10 WHOLE HOUSE SYSTEM HOUSING BIG BLUE 10" CANISTER
3 x 532b, PAE RO Water Storage Pressure Osmosis Tank Container 4G
3 x Optional: 564 Membrane Filter Housing Wrench Opener
1 x FRQ200, Flow Restrictor 200ML / min
1 x 733, Built-in Pressure Gauge 0 to 150 psi for Koolermax RO syste
2 x OPTIONAL: 567 Filter Housing Wrench Case Opener WHOLE HOUSE WH
1 x .K6150PNTF, KoolerMax K6150P RO System Shell without tank faucet
1 x FPK, 6 pcs Fitting Pack Union Connector 1/4" quarter inch
1 x WH-20, Whole House Water Treatment Carbon Block Filter System Bi
1 x 2nd stage C10 carbon block filter (replace every 6-12 months)
1 x 727, Feed Water Adapter 3/8" compression adapter 1/4" inline bal
1 x 565, Digital Pressure Gauge Tester Monitor
1 x FM-8000T, DigiFlow Digital Water Flow Meter Rate Count Down
2 x 285, Big Blue SED2005BB 20" Sediment filter WH25 WH250 WH2201
1 x Value Pack- Entire 3 Years of Replacement Filters Bundle HK120
1 x KF511UP SUBSTITUTE/Upgrade Faucet CHROME GOLD TRIM CROSS HANDLE
1 x O-RING RINGS FOR WH20 WHOLE HOUSE SYSTEM HOUSING BIG BLUE 20"
1 x 709, Automatic Shut Off Valve 4-way Four Way Valve
2 x FPK11, High Quality Fitting and Connector 1/4" (Value-Pack)
1 x PSW-380 Aquatec Pressure Switch 80 psi shut off 3/8" tubing TSO
1 x B2012, 20" Long Slim Filter Cartridge Housing RO260 RD322
1 x .K5150PNTF, KoolerMax K5150P RO System Shell without tank faucet
2 x 3rd stage C10 carbon block filter (replace every 6-12 months)
2 x PSW-280 Aquatec Pressure Switch 80 psi shut off 1/4 tubing TSO
1 x *Discontinued* RO585
1 x DB40, DI Resin Refill Bag for DI210, RD322
1 x .RO260 Aquarium 300G REVERSE OSMOSIS AEROPONICS HYDROPONICS RO
1 x Parts, Ro Water System Installation Parts Bag 1/4"
2 x CP-OR35+701 O-RING FOR WATERGENERAL BOTTOM FILTER HOUSING CASING
1 x 531, PAE RO Storage Pressure Osmosis Water Tank Container 3G
1 x 365, 4th stage TFC 50/65 US membrane filter (replace 2-3 yrs)
1 x 532w, PAE RO Storage Pressure Osmosis Water Tank Container 4G
1 x MK300, Maintenance kit for RO535, RO435, RO545, AR104H
1 x Aeroponics HighPressure Booster Pump Aquatec CDP5853 Transformer
1 x SV-110AC-14, Solenoid Valve 1/4" plastic 110VAC ESO
1 x FV-14, Bobby Float Valve Side Mount RM292-12-N NSF USA
1 x EMT-10, Empty Filter Cartridge Casing Housing
1 x TMR-220V-1A Aquatec TACS234-19 Transformer Power Supply EuroPlug
1 x KF612UP, SUBSTITUTE/Upgrade Faucet Oil Rubbed Bronze Fisnish
2 x 4044-K qty 2 Male Elbow Fitting Compression type 1/4"
1 x 741-38, Diverter Valve for RO DI Water Systems
2 x 205 2nd stage solid carbon block filter (replace every 12 month)
1 x ERP1000 Aquatec Permeate Pump Reverse Osmosis RO System USA made
2 x Wrench 2 pcs 566 Standard Filter Housing Opener Double Better
1 x MK8002, Maintenance kit for double membrane system RD322 RO260
1 x PSW-260 Aquatec Pressure Switch 60 psi shut off 1/4" tubing TSO
1 x 335UP, Upgrade Kit TFC 35 gal/day (includes US membrane filter)
1 x .AR150P, AQUARIUM & DRINKING 2 OUTPUTS Reverse Osmosis RO+DI+P
1 x 578b, TDS-3 Battery Batteries for #578 TDS Water Quality Meter
1 x 532bpg, PAE RO water pressure tank blue bladder gauge valve 4G
1 x Optional 5th or 6th Stage upgrade inline DI filter(color change)
1 x 288, CB1010BB Big Blue Carbon Block Filter 20K-50K gal 10"
1 x 3150, 4th stage TFC-150 US membrane filter (every 2-3 yrs)
1 x SET68, AQUATEC 6840 AC Pump Set Solenoid ESO Pressure Switch SET
1 x 201, 1st stage sediment filter (replace every 6-12 months)
1 x AQUATEC CDP 8852-2J03-B424 Booster Pump 220V Euro Transformer
1 x MK420, Maintenance kit for RO565
1 x PSW-350, Pressure Switch for RO Booster Pump 1/4" TSO
1 x TMR-220V-2A Aquatec TACS234-48 Transformer Power Supply EuroPlug
1 x SV-24DC-38-Brass KSD Solenoid Valve 3/8" brass 24V DC ESO
1 x SV-24DC-14, Solenoid Valve ESO 1/4" plastic, 24V DC
1 x 701, FH1014 Filter Housing Chamber Casing White Color 1/4 FPT
1 x 1st stage SF05 sediment filter (replace every 6-12 months)
1 x 752set, DC Booster Pump Transformer Solenoid Pressure Switch All
1 x KM701C, Special Koolermax Filter Housing Canister Casing 1/4 FPT

View Cart$4,671.85
Specials Log InCreate Account Checkout  Shopping Cart106 item(s)
1 x 5th or 6th Stage IC21 inline carbon filter (every 6 to 12 mons)
1 x MKP, Maintenance kit for K5150P K6150P AR150P
2 x 719, Drain Saddle Clamp / Valve
1 x ERP500 Aquatec Permeate Pump Reverse Osmosis RO System USA made
1 x 225, 5th stage Inline Alkaline filter with clear case (annual)
1 x 213, 5th or 6th stage inline carbon filter (replace in 12 mons)
1 x SVkit, Pump Shutoff Switch Kit for Aquatec Booster Pumps ESO TSO
2 x KM701, Special Koolermax Filter Housing Canister Casing 1/4 FPT
1 x SV-24AC-38, KSD Solenoid Valve ESO 3/8" brass, 24V AC
1 x *Discontinued* RO585ERP
3 x 205, 3rd stage solid carbon block filter (replace every 12month)
1 x WH-5, Whole House Water Treatment Sediment Filter System 10" Big
2 x 532wpg, PAE RO water pressure white tank bladder gauge valve 4G
1 x Annual Filter Kit Koolermax Series KPAK-3 Sediment Carbon Block
1 x 4th stage TFC150 US membrane filter (every 2-3 yrs)M150 P/N3150
1 x FM-8100T, DigiFlow Digital Water Flow Rate Meter 56" cable
2 x 4044-K Male Elbow Fitting Compression type 1/4" OD 1/4" NPT
1 x AQUATEC 8852-2J03-B424 High Flow Booster Pump 110V Transformer
1 x Optional: 566 Filter Housing Wrench Opener WaterGeneral System
1 x B2010, 20" Big Blue Filter Housing Cartridge WH20 WH25 WH250
1 x SV-24AC-14, Solenoid Valve ESO for Aquatec pump 1/4" wiring
1 x B1034, 10" Big Blue Filter Housing Cartridge WH5 WH10 WH1134
1 x O-RING FOR WH10 WHOLE HOUSE SYSTEM HOUSING BIG BLUE 10" CANISTER
3 x 532b, PAE RO Water Storage Pressure Osmosis Tank Container 4G
3 x Optional: 564 Membrane Filter Housing Wrench Opener
1 x FRQ200, Flow Restrictor 200ML / min
1 x 733, Built-in Pressure Gauge 0 to 150 psi for Koolermax RO syste
2 x OPTIONAL: 567 Filter Housing Wrench Case Opener WHOLE HOUSE WH
1 x .K6150PNTF, KoolerMax K6150P RO System Shell without tank faucet
1 x FPK, 6 pcs Fitting Pack Union Connector 1/4" quarter inch
1 x WH-20, Whole House Water Treatment Carbon Block Filter System Bi
1 x 2nd stage C10 carbon block filter (replace every 6-12 months)
1 x 727, Feed Water Adapter 3/8" compression adapter 1/4" inline bal
1 x 565, Digital Pressure Gauge Tester Monitor
1 x FM-8000T, DigiFlow Digital Water Flow Meter Rate Count Down
2 x 285, Big Blue SED2005BB 20" Sediment filter WH25 WH250 WH2201
1 x Value Pack- Entire 3 Years of Replacement Filters Bundle HK120
1 x KF511UP SUBSTITUTE/Upgrade Faucet CHROME GOLD TRIM CROSS HANDLE
1 x O-RING RINGS FOR WH20 WHOLE HOUSE SYSTEM HOUSING BIG BLUE 20"
1 x 709, Automatic Shut Off Valve 4-way Four Way Valve
2 x FPK11, High Quality Fitting and Connector 1/4" (Value-Pack)
1 x PSW-380 Aquatec Pressure Switch 80 psi shut off 3/8" tubing TSO
1 x B2012, 20" Long Slim Filter Cartridge Housing RO260 RD322
1 x .K5150PNTF, KoolerMax K5150P RO System Shell without tank faucet
2 x 3rd stage C10 carbon block filter (replace every 6-12 months)
2 x PSW-280 Aquatec Pressure Switch 80 psi shut off 1/4 tubing TSO
1 x *Discontinued* RO585
1 x DB40, DI Resin Refill Bag for DI210, RD322
1 x .RO260 Aquarium 300G REVERSE OSMOSIS AEROPONICS HYDROPONICS RO
1 x Parts, Ro Water System Installation Parts Bag 1/4"
2 x CP-OR35+701 O-RING FOR WATERGENERAL BOTTOM FILTER HOUSING CASING
1 x 531, PAE RO Storage Pressure Osmosis Water Tank Container 3G
1 x 365, 4th stage TFC 50/65 US membrane filter (replace 2-3 yrs)
1 x 532w, PAE RO Storage Pressure Osmosis Water Tank Container 4G
1 x MK300, Maintenance kit for RO535, RO435, RO545, AR104H
1 x Aeroponics HighPressure Booster Pump Aquatec CDP5853 Transformer
1 x SV-110AC-14, Solenoid Valve 1/4" plastic 110VAC ESO
1 x FV-14, Bobby Float Valve Side Mount RM292-12-N NSF USA
1 x EMT-10, Empty Filter Cartridge Casing Housing
1 x TMR-220V-1A Aquatec TACS234-19 Transformer Power Supply EuroPlug
1 x KF612UP, SUBSTITUTE/Upgrade Faucet Oil Rubbed Bronze Fisnish
2 x 4044-K qty 2 Male Elbow Fitting Compression type 1/4"
1 x 741-38, Diverter Valve for RO DI Water Systems
2 x 205 2nd stage solid carbon block filter (replace every 12 month)
1 x ERP1000 Aquatec Permeate Pump Reverse Osmosis RO System USA made
2 x Wrench 2 pcs 566 Standard Filter Housing Opener Double Better
1 x MK8002, Maintenance kit for double membrane system RD322 RO260
1 x PSW-260 Aquatec Pressure Switch 60 psi shut off 1/4" tubing TSO
1 x 335UP, Upgrade Kit TFC 35 gal/day (includes US membrane filter)
1 x .AR150P, AQUARIUM & DRINKING 2 OUTPUTS Reverse Osmosis RO+DI+P
1 x 578b, TDS-3 Battery Batteries for #578 TDS Water Quality Meter
1 x 532bpg, PAE RO water pressure tank blue bladder gauge valve 4G
1 x Optional 5th or 6th Stage upgrade inline DI filter(color change)
1 x 288, CB1010BB Big Blue Carbon Block Filter 20K-50K gal 10"
1 x 3150, 4th stage TFC-150 US membrane filter (every 2-3 yrs)
1 x SET68, AQUATEC 6840 AC Pump Set Solenoid ESO Pressure Switch SET
1 x 201, 1st stage sediment filter (replace every 6-12 months)
1 x AQUATEC CDP 8852-2J03-B424 Booster Pump 220V Euro Transformer
1 x MK420, Maintenance kit for RO565
1 x PSW-350, Pressure Switch for RO Booster Pump 1/4" TSO
1 x TMR-220V-2A Aquatec TACS234-48 Transformer Power Supply EuroPlug
1 x SV-24DC-38-Brass KSD Solenoid Valve 3/8" brass 24V DC ESO
1 x SV-24DC-14, Solenoid Valve ESO 1/4" plastic, 24V DC
1 x 701, FH1014 Filter Housing Chamber Casing White Color 1/4 FPT
1 x 1st stage SF05 sediment filter (replace every 6-12 months)
1 x 752set, DC Booster Pump Transformer Solenoid Pressure Switch All
1 x KM701C, Special Koolermax Filter Housing Canister Casing 1/4 FPT

View Cart$4,671.85

AQUATEC 8852-2J03-B424 High Flow Booster Pump 110V Transformer [8852TM25]

$110.00

Aquatec Pressure Boost pump CDP 8852 series (High flow)  3/8" and 1/4" fittings

  • Including:  pump + tranformer 120V/60Hz  + both 3/8" and 1/4" fittings
  • Aquatec model # 8852-2J03-B424
  • Filter part # HF-8852-110V   (pump + transformer+ fittings) 
  • Made in USA

This water booster pump is to boost the input water pressure.  It is usually used to increase the input water pressure for Reverse Osmosis systems. (boost pressure to 60 to 80 psi)

This pump is suitable for RO systems that is 100GPD to 200GPD

* This listing is for the pump+ transformer 120V/60hz USA plug + 3/8" and 1/4" fittings.   We have another listing that has 220V/50Hz European plug  pump +transformer.  for $10 additional, or the USA transformer, solenoid valve and pressure switch for $20 additional. Please contact us for other listings.

Benefits of using Booster pump for Reverse osmosis systems

·        For RO systems, an increase in input pressure means an increase in water production and water purity

·        RO systems will run more efficient, and have less drain water. Since it uses pressure switch and solenoid valve to turn on/off the water input, it can turn-on and turn-off more accurately than the mechanical auto-shut-off valve.

·        For large water container or open water tank, you can use float switch or level switch to control the operation of the pump as well.

·       The transformer included in the package is plugged into regular 120V/60HZ electrical outlet in USA.

 

Specifications:

Booster Pump:
Boost pressure If input water pressure is about 30 to 50 psi, the pump will boost pressure to about 60to 80 psi for RO systems
Water open flow 2.6 liter per minute or 0.69 gallons per minute
Electrical: 24VAC, 0.70Amp to 1.65amp
Connection Inlet and outlet, 3/8" quick connect fitting, also includes two reducer 3/8 to 1/4" fittings
Motor Permanent Magnet, 24VAC, enclosed
PUMP Diaphragm pump, 3 chamber, self-priming 7 feet prime. It is able to run dry

Material: Housing

Nylon

Valves

EPDM

Diaphragm

Santoprene

Fasteners

Stainless Steel
Dimension diameter = 3.5" , length = 7.5"
weight 7.5 lbs.
Transformer input 120VAC 60hz output: 24VAC 2.5Amp, Class 2, UL listed

Reviews

 Customers who bought this product also purchased

Home  |   Specials  |   Log In  |   Create Account  |   Checkout  |   Shopping Cart