Log In Log In  |  Checkout   |  36 item(s)
1 x TMR-220V-1A Aquatec TACS234-19 Transformer Power Supply EuroPlug
1 x PSW-240 Aquatec Pressure Switch 40 psi shut off 1/4" tubing TSO
1 x Special, Output Conversion Kit Convert from 1/4" to 3/8"
1 x Wrench 2 pcs 566 Standard Filter Housing Opener Double Better
1 x TMR-DC-1212, Transformer Power Supply for Delivery Demand Pump
1 x UU Clips Pair Membrane to Membrane, 2.5" to 2.5"
1 x UU Clips Pair from Bracket to Membrane Filter
1 x O-RING FOR WH10 WHOLE HOUSE SYSTEM HOUSING BIG BLUE 10" CANISTER
1 x PSW-350, Pressure Switch for RO Booster Pump 1/4" TSO
1 x TMR-UV-6W, Replacement UV Ballast Transformer 6 Watts for 602 UV
1 x PSW-380 Aquatec Pressure Switch 80 psi shut off 3/8" tubing TSO
1 x TMR-AQT-68, Transformer Power Supply Aquatec TACS114-19EP for 68
1 x TMR-AQT-2A, Transformer Power Supply Aquatec TACS114-48 for 8800
1 x Parts, Ro Water System Installation Parts Bag 1/4"
1 x PSW-2100 Aquatec Pressure Switch 100 psi shut off 1/4 tubing TSO
1 x SW SHELL, Countertop SW1 Empty System Only No Filter
1 x TMR-DC-2412, Transformer Power Supply for #752 Booster Pump
1 x MK800, Maintenance kit for AR122, AR125, HK120, RD150, RO155
1 x Optional: 564 Membrane Filter Housing Wrench Opener
1 x UC SHELL, Honeywell UC7000 Empty System Only No Filter
1 x O-RING RINGS FOR WH20 WHOLE HOUSE SYSTEM HOUSING BIG BLUE 20"
1 x N-14-1M, Nipple Fitting connector between standard RO housing
1 x OPTIONAL: 567 Filter Housing Wrench Case Opener WHOLE HOUSE WH
1 x TMR-220V-2A Aquatec TACS234-48 Transformer Power Supply EuroPlug
1 x Y3414CH, Garden Hose Y Adapter Shut-Off Valve Metal Construction
1 x SV-24AC-14, Solenoid Valve for Aquatec pump only 1/4" 24VAC ESO
1 x UU Clips Pair Membrane to Filter, 2.5" to 2"
1 x MK8002, Maintenance kit for double membrane system RD322 RO260
1 x MK420, Maintenance kit for RO565
1 x TMR-25A, 2.5 AMP Transformer Power Supply Ballast for 8800 5853
1 x UU Clips Pair Standard Filter to Standard Filter, 2" x 2"
1 x PSW-260 Aquatec Pressure Switch 60 psi shut off 1/4" tubing TSO
1 x PSW-280 Aquatec Pressure Switch 80 psi shut off 1/4 tubing TSO
1 x Y3414BR, Garden Hose Y Adapter Shutoff Valve Brass Construction
1 x PSW-3100 Aquatec Pressure Switch 100 psi shut off 3/8 tubing TSO
1 x MK550, Maintenance kit for RO585, RD102, RD106, RO6, K5, K6

View Cart$701.49
Specials Log InCreate Account Checkout  Shopping Cart36 item(s)
1 x TMR-220V-1A Aquatec TACS234-19 Transformer Power Supply EuroPlug
1 x PSW-240 Aquatec Pressure Switch 40 psi shut off 1/4" tubing TSO
1 x Special, Output Conversion Kit Convert from 1/4" to 3/8"
1 x Wrench 2 pcs 566 Standard Filter Housing Opener Double Better
1 x TMR-DC-1212, Transformer Power Supply for Delivery Demand Pump
1 x UU Clips Pair Membrane to Membrane, 2.5" to 2.5"
1 x UU Clips Pair from Bracket to Membrane Filter
1 x O-RING FOR WH10 WHOLE HOUSE SYSTEM HOUSING BIG BLUE 10" CANISTER
1 x PSW-350, Pressure Switch for RO Booster Pump 1/4" TSO
1 x TMR-UV-6W, Replacement UV Ballast Transformer 6 Watts for 602 UV
1 x PSW-380 Aquatec Pressure Switch 80 psi shut off 3/8" tubing TSO
1 x TMR-AQT-68, Transformer Power Supply Aquatec TACS114-19EP for 68
1 x TMR-AQT-2A, Transformer Power Supply Aquatec TACS114-48 for 8800
1 x Parts, Ro Water System Installation Parts Bag 1/4"
1 x PSW-2100 Aquatec Pressure Switch 100 psi shut off 1/4 tubing TSO
1 x SW SHELL, Countertop SW1 Empty System Only No Filter
1 x TMR-DC-2412, Transformer Power Supply for #752 Booster Pump
1 x MK800, Maintenance kit for AR122, AR125, HK120, RD150, RO155
1 x Optional: 564 Membrane Filter Housing Wrench Opener
1 x UC SHELL, Honeywell UC7000 Empty System Only No Filter
1 x O-RING RINGS FOR WH20 WHOLE HOUSE SYSTEM HOUSING BIG BLUE 20"
1 x N-14-1M, Nipple Fitting connector between standard RO housing
1 x OPTIONAL: 567 Filter Housing Wrench Case Opener WHOLE HOUSE WH
1 x TMR-220V-2A Aquatec TACS234-48 Transformer Power Supply EuroPlug
1 x Y3414CH, Garden Hose Y Adapter Shut-Off Valve Metal Construction
1 x SV-24AC-14, Solenoid Valve for Aquatec pump only 1/4" 24VAC ESO
1 x UU Clips Pair Membrane to Filter, 2.5" to 2"
1 x MK8002, Maintenance kit for double membrane system RD322 RO260
1 x MK420, Maintenance kit for RO565
1 x TMR-25A, 2.5 AMP Transformer Power Supply Ballast for 8800 5853
1 x UU Clips Pair Standard Filter to Standard Filter, 2" x 2"
1 x PSW-260 Aquatec Pressure Switch 60 psi shut off 1/4" tubing TSO
1 x PSW-280 Aquatec Pressure Switch 80 psi shut off 1/4 tubing TSO
1 x Y3414BR, Garden Hose Y Adapter Shutoff Valve Brass Construction
1 x PSW-3100 Aquatec Pressure Switch 100 psi shut off 3/8 tubing TSO
1 x MK550, Maintenance kit for RO585, RD102, RD106, RO6, K5, K6

View Cart$701.49

CDP6800T110V, AQUATEC Booster Pump Transformer 6840-2J03-B224 [6800T110V]

$85.00

CDP6800T110V, AQUATEC Booster Pump Transformer 6840-2J03-B224



Aquatec Pressure Boost pump CDP 6800 series (standard flow)

Pump + Transformer 120V/60Hz USA plug

Aquatec model # 6840-2J03-B224

Filter Direct part # CDP6800T110V (pump + transformer)

Made in USA

This water booster pump is to boost the input water pressure. It is usually used to increase the input water pressure for Reverse Osmosis systems. (boost pressure to 60 to 80 psi)

This pump is suitable for RO systems that is 24GPD to 100GPD

* This listing is for the pump+ transformer 120V/60hz USA plug. We have another item that has 220V/50Hz European plug pump +transformer. We also have another item that has pump, transformer, solenoid valve and pressure switch; or you can buy just the pump without a transformer.

Benefits of using Booster pump for Reverse osmosis systems

· For RO systems, an increase in input pressure means an increase in water production and water purity

· RO systems will run more efficient, and have less drain water. Since it uses pressure switch and solenoid valve to turn on/off the water input, it can turn-on and turn-off more accurately than the mechanical auto-shut-off valve.

· For large water container or open water tank, you can use float switch or level switch to control the operation of the pump as well.

· The transformer included in the package is plugged into regular 120V/60HZ electrical outlet in USA.

Specifications:

Booster Pump:
Boost pressure If input water pressure is about 30 to 50 psi, the pump will boost pressure to about 60to 80 psi for RO systems
Water open flow 1 liter per minute or 0.26 gallons per minute
Electrical: 24VAC, 0.23Amp to 0.62amp
Connection Inlet and outlet, 1/4" quick connect fitting
Motor Permanent Magnet, 24VAC, enclosed
PUMP Diaphragm pump, 3 chamber, self-priming 7 feet prime. It is able to run dry

Material: Housing

Nylon

Valves

EPDM

Diaphragm

Santoprene

Fasteners

Stainless Steel
Dimension diameter = 3.5" , length = 7"
Weight 6 lbs.
Transformer input 120VAC 60hz output: 24VAC 1Amp, Class 2, UL listed

Reviews

 Customers who bought this product also purchased

Home  |   Specials  |   Log In  |   Create Account  |   Checkout  |   Shopping Cart