Log In Log In  |  Checkout   |  29 item(s)
2 x 532w, PAE RO Storage Pressure Osmosis Water Tank Container 4G
1 x 1st stage SF05 sediment filter (replace every 6-12 months)
1 x 335UP, Upgrade Kit TFC 35 gal/day (includes US membrane filter)
1 x NM-5104, HONEYWELL COUNTERTOP WATER FILTER *DISCONTINUED* SW1
1 x Optional: 566 Filter Housing Wrench Opener WaterGeneral System
1 x 709, Automatic Shut Off Valve 4-way Four Way Valve
1 x PSW-340 Aquatec Pressure Switch 40 psi shut off 3/8" tubing TSO
1 x NM-5103, HONEYWELL COUNTERTOP WATER FILTER *DISCONTINUED* SW1
1 x .K5 KoolerMax 75GPD 5 STAGE REVERSE OSMOSIS RO FILTER SYSTEM
1 x Wrench 2 pcs 566 Standard Filter Housing Opener Double Better
1 x PSW-280 Aquatec Pressure Switch 80 psi shut off 1/4 tubing TSO
1 x 6044-combo Compression Type Fitting Elbow and Tee fitting
1 x PSW-3100 Aquatec Pressure Switch 100 psi shut off 3/8 tubing TSO
1 x Optional: 564 Membrane Filter Housing Wrench Opener
1 x KF511, Polished Chrome Cross-Handle with Gold Trim Faucet
1 x .AR125 Dual Outputs Aquarium & Home Drinking RO Filter System
1 x KF320, Elite Series: Brushed Nickel / Stainless Steel Faucet
1 x Optional 5th or 6th Stage upgrade inline DI filter(color change)
1 x CKV0402, Blue color Elbow Check Valve Elbow Type
1 x 741-14, Diverter Valve for Countertop Water Units
1 x 752, DC Booster Pump w/ Transformer
1 x MK550, Maintenance kit for RO585, RD102, RD106, RO6, K5, K6
1 x RF62, Replacement filter for CT-6000, UC7000, SW-1, and SW-1C
1 x SV-24AC-14, Solenoid Valve for Aquatec pump only 1/4" 24VAC ESO
1 x CDP8800, AQUATEC CDP8852-2J03-B424 Booster Pump Only Fitting
1 x Parts, Ro Water System Installation Parts Bag 1/4"
1 x Bundle Filter KPAK-104m Sediment Carbon Block DI Resin Membrane
1 x 602, UV Ultra Violet Sterilization Light Bulb ystem (6 watts)

View Cart$1,280.99
Specials Log InCreate Account Checkout  Shopping Cart29 item(s)
2 x 532w, PAE RO Storage Pressure Osmosis Water Tank Container 4G
1 x 1st stage SF05 sediment filter (replace every 6-12 months)
1 x 335UP, Upgrade Kit TFC 35 gal/day (includes US membrane filter)
1 x NM-5104, HONEYWELL COUNTERTOP WATER FILTER *DISCONTINUED* SW1
1 x Optional: 566 Filter Housing Wrench Opener WaterGeneral System
1 x 709, Automatic Shut Off Valve 4-way Four Way Valve
1 x PSW-340 Aquatec Pressure Switch 40 psi shut off 3/8" tubing TSO
1 x NM-5103, HONEYWELL COUNTERTOP WATER FILTER *DISCONTINUED* SW1
1 x .K5 KoolerMax 75GPD 5 STAGE REVERSE OSMOSIS RO FILTER SYSTEM
1 x Wrench 2 pcs 566 Standard Filter Housing Opener Double Better
1 x PSW-280 Aquatec Pressure Switch 80 psi shut off 1/4 tubing TSO
1 x 6044-combo Compression Type Fitting Elbow and Tee fitting
1 x PSW-3100 Aquatec Pressure Switch 100 psi shut off 3/8 tubing TSO
1 x Optional: 564 Membrane Filter Housing Wrench Opener
1 x KF511, Polished Chrome Cross-Handle with Gold Trim Faucet
1 x .AR125 Dual Outputs Aquarium & Home Drinking RO Filter System
1 x KF320, Elite Series: Brushed Nickel / Stainless Steel Faucet
1 x Optional 5th or 6th Stage upgrade inline DI filter(color change)
1 x CKV0402, Blue color Elbow Check Valve Elbow Type
1 x 741-14, Diverter Valve for Countertop Water Units
1 x 752, DC Booster Pump w/ Transformer
1 x MK550, Maintenance kit for RO585, RD102, RD106, RO6, K5, K6
1 x RF62, Replacement filter for CT-6000, UC7000, SW-1, and SW-1C
1 x SV-24AC-14, Solenoid Valve for Aquatec pump only 1/4" 24VAC ESO
1 x CDP8800, AQUATEC CDP8852-2J03-B424 Booster Pump Only Fitting
1 x Parts, Ro Water System Installation Parts Bag 1/4"
1 x Bundle Filter KPAK-104m Sediment Carbon Block DI Resin Membrane
1 x 602, UV Ultra Violet Sterilization Light Bulb ystem (6 watts)

View Cart$1,280.99

3rd stage Special High Efficiency Membrane Filter HTFC-150 [HTFC3150]

$55.00

3rd stage Special High Efficiency Membrane Filter HTFC-150

* p/n HTFC-150, (1:1 ratio) Special High Efficiency TFC type RO membrane filter

* Capacity:  100 GPD gallons per day at 60 psi input pressure.  120GPD at 80 psi, 150 GPD at 100 psi.

* This is a high efficiency 1 to 1 ratio RO membrane.  The production rate is about 260 to 300 mL per minute and the drain rate using 300 mL/min flow restrictor is about 280 to 320 mL/min depending on input pressure.  Therefore the product to drain ratio is approximately 1 to 1 (versus a conventional, typical RO membrane the product to drain ratio is 1:3 to 1:4)

* The rejection rate is pressure dependent as well.  Average NaCl rejection is about 90% to 93%

* This membrane filter is standard size.  It fits all standard size membrane housing 

* The drain flow control or the flow restrictor should be 300 mL/min  

 

Brand Name: USM RO Membrane 

Assembled and made in California, USA 

Standard size Reverse Osmosis membrane filter.  Fits all standard size RO systems and membrane housing. 

Model#  HTFC-150    100 GPD gallons per day capacity 

  

Specifications: 

This membrane fits all standard size membrane housing, standard RO systems.  

You can increase the capacity of your existing RO system by getting a higher capacity membrane filter with a matching flow restrictor, or getting a membrane module which comes with membrane filter, housing, fitting, flow restrictor, and check valve. 

  

Membrane Material:  HTFC Thin Film Composite 

Production rate: 100 gallons per day   Actual production rate varies depending on input pressure and temperature. 

Max. Operating Pressure:  130 psi 

Max. Operating Temperature:  120 F  ( 49 C) 

Recommended concentrate flow rate: 1x permeate 

(drain to pure water ratio  1:1) 

pH range: 3- 11 

Chlorine Tolerance: 0 ppm 

Dimension:  standard size 2” diameter x 11.75” length 

  

Performance: 

Applied water supply pressure: 65 psi at 77F 

Nominal Salt rejection rate: 90% to 93% 

Nominal TDS rejection rate: about 90% to 93% at 300 ppm input 

  

Features: 

Consistent quality and reliability using automated production line. 

Dry type membrane for extended shelf life 

Fits all standard membrane housings 

  

How to choose the correct RO membrane filter for your RO system? 

  1. Need to have a standard size RO system with standard membrane housing (look at photo) 
  2. Check the capacity of your RO system or RO membrane.  Capacity means how fast the membrane produces water.  The number means gallons per day (GPD).  Look for the keywords in the RO system owner’s manual or specifications. 
  3. Find the GPD rating from the membrane filter label when you take out the membrane filter. 
  4. Find the GPD rating from the drain flow rate or from the flow restrictor that is connected to the drain line. 

Flow restrictor size (drain rate) 300 mL/min.  

Reviews
Home  |   Specials  |   Log In  |   Create Account  |   Checkout  |   Shopping Cart