Log In Log In  |  Checkout   |  45 item(s)
1 x KM701C, Special Koolermax Filter Housing Canister Casing 1/4 FPT
1 x KF511, Polished Chrome Cross-Handle with Gold Trim Faucet
1 x 532b, PAE RO Water Storage Pressure Osmosis Tank Container 4G
1 x CDP6800, AQUATEC CDP6800 Booster Pump Only 6840-2J03-B224
1 x 1st stage SF05 sediment filter (replace every 6-12 months)
1 x 318, 4th stage TFC-18 US membrane filter (replace every 2-3 yrs)
1 x Optional 566 Filter Housing Wrench Case Opener KoolerMax System
1 x WS-150M, Whole House Water Softener
2 x 733, Built-in Pressure Gauge 0 to 150 psi for Koolermax RO syste
1 x DDP5800, Aquatec Demand Delivery Pump 5851-7E12 Increase Output
1 x 701, FH1014 Filter Housing Chamber Casing White Color 1/4 FPT
1 x 732, Inline Pressure Gauge 0 to 300 psi for RO filter system
1 x DM-2, Inline Dual TDS monitor (meter) for RO DI System DM2
1 x Annual Filter Kit Koolermax Series KPAK-4 Sediment Carbon Block
1 x NM-5001C, HONEYWELL COUNTERTOP WATER FILTER *DISCONTINUED* SW1
1 x TMR-220V-1A Aquatec TACS234-19 Transformer Power Supply EuroPlug
1 x WT-bac, Water Testing Kit, Bacteria Test
1 x SV-24AC-38, KSD Solenoid Valve ESO 3/8" brass, 24V AC
1 x CP-OR35+701 O-RING FOR WATERGENERAL BOTTOM FILTER HOUSING CASING
1 x WH-10, Whole House Water Treatment Carbon Filter System 10" Big
1 x PSW-240 Aquatec Pressure Switch 40 psi shut off 1/4" tubing TSO
1 x 3150, 4th stage TFC-150 US membrane filter (every 2-3 yrs)
1 x AQUATEC CDP 8852-2J03-B424 Booster Pump 220V Euro Transformer
1 x 205 2nd stage solid carbon block filter (replace every 12 month)
1 x 773, AC Booster Pump Assembly Large 150-200GPD RO systems SET
1 x 565, Digital Pressure Gauge Tester Monitor
1 x Wrench 2 pcs 566 Standard Filter Housing Opener Double Better
1 x TMR-AQT-68, Transformer Power Supply Aquatec TACS114-19EP for 68
1 x TMR-DC-1212, Transformer Power Supply for Delivery Demand Pump
1 x SV-24DC-38-Brass KSD Solenoid Valve 3/8" brass 24V DC ESO
2 x 201, 1st stage sediment filter (replace every 6-12 months)
1 x PSW-380 Aquatec Pressure Switch 80 psi shut off 3/8" tubing TSO
1 x 3/4" NPT Digiflow Digital Flow Meter count up total Water Gallon
1 x WH-5, Whole House Water Treatment Sediment Filter System 10" Big
1 x SET8855-300 Aquatec 5853 Booster Pump Assembly for 300GPD RO Sys
1 x 5th or 6th Stage IC21 inline carbon filter (every 6 to 12 mons)
1 x MK800, Maintenance kit for AR122, AR125, HK120, RD150, RO155
1 x 310, 2nd stage CTA 10 US Membrane filter
1 x SET68, AQUATEC 6840 AC Pump Set Solenoid ESO Pressure Switch SET
1 x Value Pack- Entire 3 Years of Replacement Filters Bundle RO155
1 x CDP8800, AQUATEC CDP8852-2J03-B424 Booster Pump Only Fitting
1 x Optional 225UP 5th stage Inline Alkaline upgrade(includes media)
1 x 818, DI Resin Refill Bag 16oz (good for up to three refills)

View Cart$4,798.00
Specials Log InCreate Account Checkout  Shopping Cart45 item(s)
1 x KM701C, Special Koolermax Filter Housing Canister Casing 1/4 FPT
1 x KF511, Polished Chrome Cross-Handle with Gold Trim Faucet
1 x 532b, PAE RO Water Storage Pressure Osmosis Tank Container 4G
1 x CDP6800, AQUATEC CDP6800 Booster Pump Only 6840-2J03-B224
1 x 1st stage SF05 sediment filter (replace every 6-12 months)
1 x 318, 4th stage TFC-18 US membrane filter (replace every 2-3 yrs)
1 x Optional 566 Filter Housing Wrench Case Opener KoolerMax System
1 x WS-150M, Whole House Water Softener
2 x 733, Built-in Pressure Gauge 0 to 150 psi for Koolermax RO syste
1 x DDP5800, Aquatec Demand Delivery Pump 5851-7E12 Increase Output
1 x 701, FH1014 Filter Housing Chamber Casing White Color 1/4 FPT
1 x 732, Inline Pressure Gauge 0 to 300 psi for RO filter system
1 x DM-2, Inline Dual TDS monitor (meter) for RO DI System DM2
1 x Annual Filter Kit Koolermax Series KPAK-4 Sediment Carbon Block
1 x NM-5001C, HONEYWELL COUNTERTOP WATER FILTER *DISCONTINUED* SW1
1 x TMR-220V-1A Aquatec TACS234-19 Transformer Power Supply EuroPlug
1 x WT-bac, Water Testing Kit, Bacteria Test
1 x SV-24AC-38, KSD Solenoid Valve ESO 3/8" brass, 24V AC
1 x CP-OR35+701 O-RING FOR WATERGENERAL BOTTOM FILTER HOUSING CASING
1 x WH-10, Whole House Water Treatment Carbon Filter System 10" Big
1 x PSW-240 Aquatec Pressure Switch 40 psi shut off 1/4" tubing TSO
1 x 3150, 4th stage TFC-150 US membrane filter (every 2-3 yrs)
1 x AQUATEC CDP 8852-2J03-B424 Booster Pump 220V Euro Transformer
1 x 205 2nd stage solid carbon block filter (replace every 12 month)
1 x 773, AC Booster Pump Assembly Large 150-200GPD RO systems SET
1 x 565, Digital Pressure Gauge Tester Monitor
1 x Wrench 2 pcs 566 Standard Filter Housing Opener Double Better
1 x TMR-AQT-68, Transformer Power Supply Aquatec TACS114-19EP for 68
1 x TMR-DC-1212, Transformer Power Supply for Delivery Demand Pump
1 x SV-24DC-38-Brass KSD Solenoid Valve 3/8" brass 24V DC ESO
2 x 201, 1st stage sediment filter (replace every 6-12 months)
1 x PSW-380 Aquatec Pressure Switch 80 psi shut off 3/8" tubing TSO
1 x 3/4" NPT Digiflow Digital Flow Meter count up total Water Gallon
1 x WH-5, Whole House Water Treatment Sediment Filter System 10" Big
1 x SET8855-300 Aquatec 5853 Booster Pump Assembly for 300GPD RO Sys
1 x 5th or 6th Stage IC21 inline carbon filter (every 6 to 12 mons)
1 x MK800, Maintenance kit for AR122, AR125, HK120, RD150, RO155
1 x 310, 2nd stage CTA 10 US Membrane filter
1 x SET68, AQUATEC 6840 AC Pump Set Solenoid ESO Pressure Switch SET
1 x Value Pack- Entire 3 Years of Replacement Filters Bundle RO155
1 x CDP8800, AQUATEC CDP8852-2J03-B424 Booster Pump Only Fitting
1 x Optional 225UP 5th stage Inline Alkaline upgrade(includes media)
1 x 818, DI Resin Refill Bag 16oz (good for up to three refills)

View Cart$4,798.00
Information

Booster pump for misting application:

The booster pump would boost water supply pressure if you put a RO system after it or if you put misting nozzle after the pump. The pump will not increase pressure if the output is OPEN, meaning not connected to anything.


The pump would increase the input pressure if the output flow is less than the specified flow rate of “open flow” For example, if a pump is rated as 2.5 L/min. at open flow, then when you install a misting nozzle after the pump and the nozzle flow rate is less than 2.5 liters per minute, then the pressure will increase. You can use a pressure gauge to measure the output pressure. For misting application, you can connect one nozzle first, then measure the pressure, then connect 2, 3, 4 nozzles and measure the pressure. The boost pressure would drop when you have multiple nozzles. How many nozzles can you installed per pump? This depends on the input pressure and the combine flow rate of the nozzles. You can find the answer by experimenting it. For misting application, you should place the pump below the water level, preferably on the floor.
Continue