Log In Log In  |  Checkout   |  37 item(s)
2 x 205 2nd stage solid carbon block filter (replace every 12 month)
2 x 733, Built-in Pressure Gauge 0 to 150 psi for Koolermax RO syste
1 x DB40, DI Resin Refill Bag for DI210, RD322
1 x Optional: 564 Membrane Filter Housing Wrench Opener
1 x SET88 Aquatec 8852 AC Booster pump Solenoid ESO Pressure Switch
1 x 1st stage SF05 sediment filter (replace every 6-12 months)
1 x 720, Feed Water Adapter with Needle Valve
1 x 335, 4th stage TFC 35/45 US membrane filter (every 2-3 years)
1 x FK-53, Replacement Filter Pack SED2005 CB2010 for RD322 RO260
1 x CP-OR35+701 O-RING FOR WATERGENERAL BOTTOM FILTER HOUSING CASING
1 x PSW-340 Aquatec Pressure Switch 40 psi shut off 3/8" tubing TSO
1 x 759, Aquatec Demand Delivery Pump 5853-7E12-J524 Commercial 1.7G
1 x DM-2, Inline Dual TDS monitor (meter) for RO DI System DM2
1 x TMR-UV-6W, Replacement UV Ballast Transformer 6 Watts for 602 UV
3 x 205, 3rd stage solid carbon block filter (replace every 12month)
1 x 741-14, Diverter Valve for Countertop Water Units
1 x 4044-K qty 2 Male Elbow Fitting Compression type 1/4"
1 x O-RING FOR WH10 WHOLE HOUSE SYSTEM HOUSING BIG BLUE 10" CANISTER
1 x 602, UV Ultra Violet Sterilization Light Bulb ystem (6 watts)
1 x 7044-K Union Tee Connector Fitting Compression type 1/4"
2 x 565, Digital Pressure Gauge Tester Monitor
1 x FM10, STEEL BRACKET SINGLE HOUSING MOUNTING SYSTEM
1 x 318, 4th stage TFC-18 US membrane filter (replace every 2-3 yrs)
1 x B2012, 20" Long Slim Filter Cartridge Housing RO260 RD322
2 x Wrench 2 pcs 566 Standard Filter Housing Opener Double Better
1 x 532b, PAE RO Water Storage Pressure Osmosis Tank Container 4G
1 x MK800, Maintenance kit for AR122, AR125, HK120, RD150, RO155
1 x SV-110AC-14, Solenoid Valve 1/4" plastic 110VAC ESO
1 x 2nd stage C10 carbon block filter (replace every 6-12 months)
1 x KF310, Elite Series: Polish Chrome Drinking Water Faucet
1 x 285, Big Blue SED2005BB 20" Sediment filter WH25 WH250 WH2201

View Cart$1,031.95
Specials Log InCreate Account Checkout  Shopping Cart37 item(s)
2 x 205 2nd stage solid carbon block filter (replace every 12 month)
2 x 733, Built-in Pressure Gauge 0 to 150 psi for Koolermax RO syste
1 x DB40, DI Resin Refill Bag for DI210, RD322
1 x Optional: 564 Membrane Filter Housing Wrench Opener
1 x SET88 Aquatec 8852 AC Booster pump Solenoid ESO Pressure Switch
1 x 1st stage SF05 sediment filter (replace every 6-12 months)
1 x 720, Feed Water Adapter with Needle Valve
1 x 335, 4th stage TFC 35/45 US membrane filter (every 2-3 years)
1 x FK-53, Replacement Filter Pack SED2005 CB2010 for RD322 RO260
1 x CP-OR35+701 O-RING FOR WATERGENERAL BOTTOM FILTER HOUSING CASING
1 x PSW-340 Aquatec Pressure Switch 40 psi shut off 3/8" tubing TSO
1 x 759, Aquatec Demand Delivery Pump 5853-7E12-J524 Commercial 1.7G
1 x DM-2, Inline Dual TDS monitor (meter) for RO DI System DM2
1 x TMR-UV-6W, Replacement UV Ballast Transformer 6 Watts for 602 UV
3 x 205, 3rd stage solid carbon block filter (replace every 12month)
1 x 741-14, Diverter Valve for Countertop Water Units
1 x 4044-K qty 2 Male Elbow Fitting Compression type 1/4"
1 x O-RING FOR WH10 WHOLE HOUSE SYSTEM HOUSING BIG BLUE 10" CANISTER
1 x 602, UV Ultra Violet Sterilization Light Bulb ystem (6 watts)
1 x 7044-K Union Tee Connector Fitting Compression type 1/4"
2 x 565, Digital Pressure Gauge Tester Monitor
1 x FM10, STEEL BRACKET SINGLE HOUSING MOUNTING SYSTEM
1 x 318, 4th stage TFC-18 US membrane filter (replace every 2-3 yrs)
1 x B2012, 20" Long Slim Filter Cartridge Housing RO260 RD322
2 x Wrench 2 pcs 566 Standard Filter Housing Opener Double Better
1 x 532b, PAE RO Water Storage Pressure Osmosis Tank Container 4G
1 x MK800, Maintenance kit for AR122, AR125, HK120, RD150, RO155
1 x SV-110AC-14, Solenoid Valve 1/4" plastic 110VAC ESO
1 x 2nd stage C10 carbon block filter (replace every 6-12 months)
1 x KF310, Elite Series: Polish Chrome Drinking Water Faucet
1 x 285, Big Blue SED2005BB 20" Sediment filter WH25 WH250 WH2201

View Cart$1,031.95
Information

Booster pump for misting application:

The booster pump would boost water supply pressure if you put a RO system after it or if you put misting nozzle after the pump. The pump will not increase pressure if the output is OPEN, meaning not connected to anything.


The pump would increase the input pressure if the output flow is less than the specified flow rate of “open flow” For example, if a pump is rated as 2.5 L/min. at open flow, then when you install a misting nozzle after the pump and the nozzle flow rate is less than 2.5 liters per minute, then the pressure will increase. You can use a pressure gauge to measure the output pressure. For misting application, you can connect one nozzle first, then measure the pressure, then connect 2, 3, 4 nozzles and measure the pressure. The boost pressure would drop when you have multiple nozzles. How many nozzles can you installed per pump? This depends on the input pressure and the combine flow rate of the nozzles. You can find the answer by experimenting it. For misting application, you should place the pump below the water level, preferably on the floor.
Continue
Home  |   Specials  |   Log In  |   Create Account  |   Checkout  |   Shopping Cart