Log In Log In  |  Checkout   |  28 item(s)
1 x NM-5102, HONEYWELL COUNTERTOP WATER FILTER *DISCONTINUED* SW1
1 x SC208, Specialty Filter Iron Lead and Heavy Metal Removal Filter
1 x SET8855 Aquatec 5853 Booster Pump Assembly for Aeroponics System
1 x 531, PAE RO Storage Pressure Osmosis Water Tank Container 3G
1 x Special Filter Kit Koolermax dealer distribution kit
1 x TMR-25A, 2.5 AMP Transformer Power Supply Ballast for 8800 5853
2 x CP-OR35+701 O-RING FOR WATERGENERAL BOTTOM FILTER HOUSING CASING
1 x 204, 2nd stage GAC filter (replace every 6-12 months)
1 x 673, Replacement UV Lamp Light for 602 (6 Watts)
1 x 532w, PAE RO Storage Pressure Osmosis Water Tank Container 4G
1 x SET68, AQUATEC 6840 AC Pump Set Solenoid ESO Pressure Switch SET
1 x 3rd stage C10 carbon block filter (replace every 6-12 months)
1 x AQUATEC 8852-2J03-B424 High Flow Booster Pump 110V Transformer
1 x FM90, STEEL BRACKET SINGLE HOUSING MOUNTING BIG BLUE WH SYSTEM
1 x EMT-10, Empty Filter Cartridge Casing Housing
1 x CP-OR55, O-RING FOR MEMBRANE FILTER HOUSING WaterGeneral Systems
1 x 213, 5th stage inline carbon postfilter (replace every 12months)
1 x PSW-2100 Aquatec Pressure Switch 100 psi shut off 1/4 tubing TSO
1 x 213, 4th stage inline carbon filter (replace every 12 months)
1 x OPTIONAL: 567 Filter Housing Wrench Case Opener WHOLE HOUSE WH
1 x MK550, Maintenance kit for RO585, RD102, RD106, RO6, K5, K6
2 x 532b, PAE RO Water Storage Pressure Osmosis Tank Container 4G
1 x CBV-0404, Tank Ball Valve to 1/4 tubing *standard RO tank size*
1 x FM60, STEEL BRACKET TRIPLE HOUSING 10" STANDARD FOR RO MOUNT
1 x HK120-P-TK-220V for EURO 220V / 50Hz
1 x MK225, Maintenance kit for Honeywell RO9100 Filtercold RO5 AV180

View Cart$1,364.00
Specials Log InCreate Account Checkout  Shopping Cart28 item(s)
1 x NM-5102, HONEYWELL COUNTERTOP WATER FILTER *DISCONTINUED* SW1
1 x SC208, Specialty Filter Iron Lead and Heavy Metal Removal Filter
1 x SET8855 Aquatec 5853 Booster Pump Assembly for Aeroponics System
1 x 531, PAE RO Storage Pressure Osmosis Water Tank Container 3G
1 x Special Filter Kit Koolermax dealer distribution kit
1 x TMR-25A, 2.5 AMP Transformer Power Supply Ballast for 8800 5853
2 x CP-OR35+701 O-RING FOR WATERGENERAL BOTTOM FILTER HOUSING CASING
1 x 204, 2nd stage GAC filter (replace every 6-12 months)
1 x 673, Replacement UV Lamp Light for 602 (6 Watts)
1 x 532w, PAE RO Storage Pressure Osmosis Water Tank Container 4G
1 x SET68, AQUATEC 6840 AC Pump Set Solenoid ESO Pressure Switch SET
1 x 3rd stage C10 carbon block filter (replace every 6-12 months)
1 x AQUATEC 8852-2J03-B424 High Flow Booster Pump 110V Transformer
1 x FM90, STEEL BRACKET SINGLE HOUSING MOUNTING BIG BLUE WH SYSTEM
1 x EMT-10, Empty Filter Cartridge Casing Housing
1 x CP-OR55, O-RING FOR MEMBRANE FILTER HOUSING WaterGeneral Systems
1 x 213, 5th stage inline carbon postfilter (replace every 12months)
1 x PSW-2100 Aquatec Pressure Switch 100 psi shut off 1/4 tubing TSO
1 x 213, 4th stage inline carbon filter (replace every 12 months)
1 x OPTIONAL: 567 Filter Housing Wrench Case Opener WHOLE HOUSE WH
1 x MK550, Maintenance kit for RO585, RD102, RD106, RO6, K5, K6
2 x 532b, PAE RO Water Storage Pressure Osmosis Tank Container 4G
1 x CBV-0404, Tank Ball Valve to 1/4 tubing *standard RO tank size*
1 x FM60, STEEL BRACKET TRIPLE HOUSING 10" STANDARD FOR RO MOUNT
1 x HK120-P-TK-220V for EURO 220V / 50Hz
1 x MK225, Maintenance kit for Honeywell RO9100 Filtercold RO5 AV180

View Cart$1,364.00
Information

Flow meter measurement accuracy:

All meters are built in the same way and use the same formula to calculate the flow rate. There are many situations that affect the accuracy of the measurements. Trying to avoid them would increase the accuracy.

1. If there are air bubbles in the lines. Usually this might occur when using a pump to transfer water.

2. Incidents when the flow of water is too slow or too fast that is out of the measuring range. This meter has a range of 0.45 gpm and 3.7 gpm. If the flow of water is sometimes falls out of range, then it can't be counted or measured.
If you are not able to modify your setup in any way to avoid the effects of inaccuracy. You can apply a correction factor to the measurement. For example, take two to three different measurement to find the correction factor for the total count. Use a container that you can tell it has 1 gallon, 2 gallons, and 5 gallons. Use a stop watch to time how much time it takes for the meter to advance 1 gallon. If it takes 70 seconds to advance 1 gallon, then do the same test again to see if the time is about 70 seconds again. Then do the same test for 2 gallons of water. The time should be about 2 times 70 seconds or 140 seconds. If you do this test few times, and the results are the same that means you have found the correction factor. So, the correction factor in this case is 70 sec/ 60sec = 1.1666. If the meter reads 125 gallons then the actual value is about 125 * 1.1666 = 146 gallons.


Please understand most digital flow meters measures similarly. Industrial grade or commercial grade high accuracy flow meter are hundreds and thousands of dollars. Using a simple correction factor you can achieve higher accuracy regardless of your setup.
Continue
Home  |   Specials  |   Log In  |   Create Account  |   Checkout  |   Shopping Cart