Log In Log In  |  Checkout   |  24 item(s)
1 x 201, 1st stage sediment filter (replace every 6-12 months)
1 x PSW-280 Aquatec Pressure Switch 80 psi shut off 1/4 tubing TSO
1 x MK300, Maintenance kit for RO535, RO435, RO545, AR104H
1 x ERP1000 Aquatec Permeate Pump Reverse Osmosis RO System USA made
1 x 773, AC Booster Pump Assembly Large 150-200GPD RO systems SET
1 x CBV-38, Tank Ball Valve to 3/8 tubing
1 x *Discontinued* RD102
1 x FPK, 6 pcs Fitting Pack Union Connector 1/2 x 3/8 inch
1 x Aeroponics HighPressure Booster Pump Aquatec CDP5853 Transformer
1 x Annual Filter Kit Koolermax Series KPAK-3 Sediment Carbon Block
1 x Optional 5th or 6th Stage upgrade inline DI filter(color change)
1 x 581, Ice Maker Hookup Kit Connect RO water to Fridge Ice Maker
1 x 2542-K, Female Connector 1/4 OD 1/8 FNPT Compression Fitting
1 x 6044-combo Compression Type Fitting Elbow and Tee fitting
1 x 1070, PAE LARGE RO Storage Pressure Tank 14 GALLON 14G
1 x 818, DI Resin Refill Bag 16oz (good for up to three refills)
1 x 5th or 6th Stage IC21 inline carbon filter (every 6 to 12 mons)
1 x FPK, 6 pcs Fitting Pack Union Connector 1/4" quarter inch
1 x 324, 4th stage TFC-24 US membrane filter (replace every 2-3 yrs)
1 x Optional: 566 Filter Housing Wrench Opener WaterGeneral System
1 x 2nd stage C10 carbon block filter (replace every 6-12 months)
1 x PSW-340 Aquatec Pressure Switch 40 psi shut off 3/8" tubing TSO
1 x Optional 566 Filter Housing Wrench Case Opener KoolerMax System
1 x FPK, 6 pcs Fitting Pack Union Connector 3/8 x 1/4 inch

View Cart$947.39
Specials Log InCreate Account Checkout  Shopping Cart24 item(s)
1 x 201, 1st stage sediment filter (replace every 6-12 months)
1 x PSW-280 Aquatec Pressure Switch 80 psi shut off 1/4 tubing TSO
1 x MK300, Maintenance kit for RO535, RO435, RO545, AR104H
1 x ERP1000 Aquatec Permeate Pump Reverse Osmosis RO System USA made
1 x 773, AC Booster Pump Assembly Large 150-200GPD RO systems SET
1 x CBV-38, Tank Ball Valve to 3/8 tubing
1 x *Discontinued* RD102
1 x FPK, 6 pcs Fitting Pack Union Connector 1/2 x 3/8 inch
1 x Aeroponics HighPressure Booster Pump Aquatec CDP5853 Transformer
1 x Annual Filter Kit Koolermax Series KPAK-3 Sediment Carbon Block
1 x Optional 5th or 6th Stage upgrade inline DI filter(color change)
1 x 581, Ice Maker Hookup Kit Connect RO water to Fridge Ice Maker
1 x 2542-K, Female Connector 1/4 OD 1/8 FNPT Compression Fitting
1 x 6044-combo Compression Type Fitting Elbow and Tee fitting
1 x 1070, PAE LARGE RO Storage Pressure Tank 14 GALLON 14G
1 x 818, DI Resin Refill Bag 16oz (good for up to three refills)
1 x 5th or 6th Stage IC21 inline carbon filter (every 6 to 12 mons)
1 x FPK, 6 pcs Fitting Pack Union Connector 1/4" quarter inch
1 x 324, 4th stage TFC-24 US membrane filter (replace every 2-3 yrs)
1 x Optional: 566 Filter Housing Wrench Opener WaterGeneral System
1 x 2nd stage C10 carbon block filter (replace every 6-12 months)
1 x PSW-340 Aquatec Pressure Switch 40 psi shut off 3/8" tubing TSO
1 x Optional 566 Filter Housing Wrench Case Opener KoolerMax System
1 x FPK, 6 pcs Fitting Pack Union Connector 3/8 x 1/4 inch

View Cart$947.39
Information

Flow meter measurement accuracy:

All meters are built in the same way and use the same formula to calculate the flow rate. There are many situations that affect the accuracy of the measurements. Trying to avoid them would increase the accuracy.

1. If there are air bubbles in the lines. Usually this might occur when using a pump to transfer water.

2. Incidents when the flow of water is too slow or too fast that is out of the measuring range. This meter has a range of 0.45 gpm and 3.7 gpm. If the flow of water is sometimes falls out of range, then it can't be counted or measured.
If you are not able to modify your setup in any way to avoid the effects of inaccuracy. You can apply a correction factor to the measurement. For example, take two to three different measurement to find the correction factor for the total count. Use a container that you can tell it has 1 gallon, 2 gallons, and 5 gallons. Use a stop watch to time how much time it takes for the meter to advance 1 gallon. If it takes 70 seconds to advance 1 gallon, then do the same test again to see if the time is about 70 seconds again. Then do the same test for 2 gallons of water. The time should be about 2 times 70 seconds or 140 seconds. If you do this test few times, and the results are the same that means you have found the correction factor. So, the correction factor in this case is 70 sec/ 60sec = 1.1666. If the meter reads 125 gallons then the actual value is about 125 * 1.1666 = 146 gallons.


Please understand most digital flow meters measures similarly. Industrial grade or commercial grade high accuracy flow meter are hundreds and thousands of dollars. Using a simple correction factor you can achieve higher accuracy regardless of your setup.
Continue
Home  |   Specials  |   Log In  |   Create Account  |   Checkout  |   Shopping Cart