Log In Log In  |  Checkout   |  34 item(s)
2 x Wrench 2 pcs 566 Standard Filter Housing Opener Double Better
1 x 701C, FHC1014 Filter Housing Chamber Casing Clear Color 1/4 FPT
2 x CPR-150G, Pressure Regulator with Pressure Gauge (0-125 psi)
1 x 752, DC Booster Pump w/ Transformer
1 x FM60, STEEL BRACKET TRIPLE HOUSING 10" STANDARD FOR RO MOUNT
1 x 752set, DC Booster Pump Transformer Solenoid Pressure Switch All
1 x PSW-2100 Aquatec Pressure Switch 100 psi shut off 1/4 tubing TSO
1 x Parts, Ro Water System Installation Parts Bag 1/4"
2 x 2nd stage C10 carbon block filter (replace every 6-12 months)
1 x .AR125 Dual Outputs Aquarium & Home Drinking RO Filter System
1 x 4th stage TFC 75/85 US membrane filter (every 2-3 yrs) M75
1 x WSACF-150T, Whole House Water Treatment ACF-150T
1 x Optional: 564 Membrane Filter Housing Wrench Opener
3 x OPTIONAL: 567 Filter Housing Wrench Case Opener WHOLE HOUSE WH
1 x PSW-260 Aquatec Pressure Switch 60 psi shut off 1/4" tubing TSO
2 x 205, 3rd stage solid carbon block filter (replace every 12month)
1 x .SW-1C COUNTERTOP WATER FILTER SYSTEM (CLEAR HOUSING)
1 x Optional: 566 Filter Housing Wrench Opener WaterGeneral System
2 x 4th stage TFC150 US membrane filter (every 2-3 yrs)M150 P/N3150
1 x SVkit, Pump Shutoff Switch Kit for Aquatec Booster Pumps ESO TSO
1 x NM-5103, HONEYWELL COUNTERTOP WATER FILTER *DISCONTINUED* SW1
1 x SV-24AC-14, Solenoid Valve for Aquatec pump only 1/4" 24VAC ESO
1 x KM701C, Special Koolermax Filter Housing Canister Casing 1/4 FPT
1 x SET88 Aquatec 8852 AC Booster pump Solenoid ESO Pressure Switch
1 x DM-2, Inline Dual TDS monitor (meter) for RO DI System DM2
1 x FKD-66, Replacement Filter Pack SED2005 CB2010 DB40 for RD322
1 x .SW-1 COUNTERTOP WATER FILTER SYSTEM (WHITE HOUSING)

View Cart$3,780.00
Specials Log InCreate Account Checkout  Shopping Cart34 item(s)
2 x Wrench 2 pcs 566 Standard Filter Housing Opener Double Better
1 x 701C, FHC1014 Filter Housing Chamber Casing Clear Color 1/4 FPT
2 x CPR-150G, Pressure Regulator with Pressure Gauge (0-125 psi)
1 x 752, DC Booster Pump w/ Transformer
1 x FM60, STEEL BRACKET TRIPLE HOUSING 10" STANDARD FOR RO MOUNT
1 x 752set, DC Booster Pump Transformer Solenoid Pressure Switch All
1 x PSW-2100 Aquatec Pressure Switch 100 psi shut off 1/4 tubing TSO
1 x Parts, Ro Water System Installation Parts Bag 1/4"
2 x 2nd stage C10 carbon block filter (replace every 6-12 months)
1 x .AR125 Dual Outputs Aquarium & Home Drinking RO Filter System
1 x 4th stage TFC 75/85 US membrane filter (every 2-3 yrs) M75
1 x WSACF-150T, Whole House Water Treatment ACF-150T
1 x Optional: 564 Membrane Filter Housing Wrench Opener
3 x OPTIONAL: 567 Filter Housing Wrench Case Opener WHOLE HOUSE WH
1 x PSW-260 Aquatec Pressure Switch 60 psi shut off 1/4" tubing TSO
2 x 205, 3rd stage solid carbon block filter (replace every 12month)
1 x .SW-1C COUNTERTOP WATER FILTER SYSTEM (CLEAR HOUSING)
1 x Optional: 566 Filter Housing Wrench Opener WaterGeneral System
2 x 4th stage TFC150 US membrane filter (every 2-3 yrs)M150 P/N3150
1 x SVkit, Pump Shutoff Switch Kit for Aquatec Booster Pumps ESO TSO
1 x NM-5103, HONEYWELL COUNTERTOP WATER FILTER *DISCONTINUED* SW1
1 x SV-24AC-14, Solenoid Valve for Aquatec pump only 1/4" 24VAC ESO
1 x KM701C, Special Koolermax Filter Housing Canister Casing 1/4 FPT
1 x SET88 Aquatec 8852 AC Booster pump Solenoid ESO Pressure Switch
1 x DM-2, Inline Dual TDS monitor (meter) for RO DI System DM2
1 x FKD-66, Replacement Filter Pack SED2005 CB2010 DB40 for RD322
1 x .SW-1 COUNTERTOP WATER FILTER SYSTEM (WHITE HOUSING)

View Cart$3,780.00
Information

Flow meter measurement accuracy:

All meters are built in the same way and use the same formula to calculate the flow rate. There are many situations that affect the accuracy of the measurements. Trying to avoid them would increase the accuracy.

1. If there are air bubbles in the lines. Usually this might occur when using a pump to transfer water.

2. Incidents when the flow of water is too slow or too fast that is out of the measuring range. This meter has a range of 0.45 gpm and 3.7 gpm. If the flow of water is sometimes falls out of range, then it can't be counted or measured.
If you are not able to modify your setup in any way to avoid the effects of inaccuracy. You can apply a correction factor to the measurement. For example, take two to three different measurement to find the correction factor for the total count. Use a container that you can tell it has 1 gallon, 2 gallons, and 5 gallons. Use a stop watch to time how much time it takes for the meter to advance 1 gallon. If it takes 70 seconds to advance 1 gallon, then do the same test again to see if the time is about 70 seconds again. Then do the same test for 2 gallons of water. The time should be about 2 times 70 seconds or 140 seconds. If you do this test few times, and the results are the same that means you have found the correction factor. So, the correction factor in this case is 70 sec/ 60sec = 1.1666. If the meter reads 125 gallons then the actual value is about 125 * 1.1666 = 146 gallons.


Please understand most digital flow meters measures similarly. Industrial grade or commercial grade high accuracy flow meter are hundreds and thousands of dollars. Using a simple correction factor you can achieve higher accuracy regardless of your setup.
Continue
Home  |   Specials  |   Log In  |   Create Account  |   Checkout  |   Shopping Cart