Log In Log In  |  Checkout   |  50 item(s)
1 x Panel 1/2" 6710M-44TM Digital Flow Meter count up Gallon 115V
1 x 745, AFAN0409 Female Garden Hose / Laundry Hose Adapter
3 x 201, 1st stage sediment filter (replace every 6-12 months)
1 x 602, UV Ultra Violet Sterilization Light Bulb ystem (6 watts)
1 x 752, DC Booster Pump w/ Transformer
1 x FV-14, Bobby Float Valve Side Mount RM292-12-N NSF USA
2 x 701, FH1014 Filter Housing Chamber Casing White Color 1/4 FPT
1 x SW SHELL, Countertop SW1 Empty System Only No Filter
1 x 215, 5th or 6th Stage Refillable inline DI filter (color change)
2 x KM701C, Special Koolermax Filter Housing Canister Casing 1/4 FPT
1 x PSW-350, Pressure Switch for RO Booster Pump 1/4" TSO
1 x Optional: 566 Filter Housing Wrench Opener WaterGeneral System
1 x 818, DI Resin Refill Bag 16oz (good for up to three refills)
1 x 285, Big Blue SED2005BB 20" Sediment filter WH25 WH250 WH2201
1 x DM-1, Inline Dual TDS monitor (meter) for RO DI System DM1
1 x 741-38, Diverter Valve for RO DI Water Systems
2 x Optional 5th or 6th Stage upgrade inline DI filter(color change)
1 x 1st stage SF05 sediment filter (replace every 6-12 months)
1 x Special, Single Stage Housing Bracket Shell Connection Kit
1 x 532bpg, PAE RO water pressure tank blue bladder gauge valve 4G
1 x B2010, 20" Big Blue Filter Housing Cartridge WH20 WH25 WH250
1 x AQF-600-105, Flow Meter Panel Mount 1/2" MPT
1 x Value Pack- Entire 3 Years of Replacement Filters Bundle RD322
2 x 3rd stage C10 carbon block filter (replace every 6-12 months)
1 x Value Pack- Entire 3 Years of Replacement Filters Bundle AR150P
1 x FM-8100T, DigiFlow Digital Water Flow Rate Meter 56" cable
3 x Optional: 564 Membrane Filter Housing Wrench Opener
1 x 3150, 5th stage TFC-150 US membrane filter (every 2-3 years)
1 x SV-24DC-38-Brass KSD Solenoid Valve 3/8" brass 24V DC ESO
1 x 5th stage 225 Inline Alkaline filter with clear housing (annual)
1 x 719, Drain Saddle Clamp / Valve
1 x UU Clips Pair Membrane to Filter, 2.5" to 2"
1 x 205 2nd stage solid carbon block filter (replace every 12 month)
1 x B1034, 10" Big Blue Filter Housing Cartridge WH5 WH10 WH1134
1 x 532b, PAE RO Water Storage Pressure Osmosis Tank Container 4G
1 x 399, 4th stage TFC-100 US membrane filter (every 2-3 yrs)
1 x 671C, Replacement UV Lamp Light for 609C (16 Watt)
1 x 1/2" NPT Digiflow Digital Flow Meter count up total Water Gallon
1 x PSW-340 Aquatec Pressure Switch 40 psi shut off 3/8" tubing TSO
1 x 214, Clear Inline Filter Cartridge Empty Case
1 x MKP, Maintenance kit for K5150P K6150P AR150P
1 x 741-14, Diverter Valve for Countertop Water Units

View Cart$1,711.99
Specials Log InCreate Account Checkout  Shopping Cart50 item(s)
1 x Panel 1/2" 6710M-44TM Digital Flow Meter count up Gallon 115V
1 x 745, AFAN0409 Female Garden Hose / Laundry Hose Adapter
3 x 201, 1st stage sediment filter (replace every 6-12 months)
1 x 602, UV Ultra Violet Sterilization Light Bulb ystem (6 watts)
1 x 752, DC Booster Pump w/ Transformer
1 x FV-14, Bobby Float Valve Side Mount RM292-12-N NSF USA
2 x 701, FH1014 Filter Housing Chamber Casing White Color 1/4 FPT
1 x SW SHELL, Countertop SW1 Empty System Only No Filter
1 x 215, 5th or 6th Stage Refillable inline DI filter (color change)
2 x KM701C, Special Koolermax Filter Housing Canister Casing 1/4 FPT
1 x PSW-350, Pressure Switch for RO Booster Pump 1/4" TSO
1 x Optional: 566 Filter Housing Wrench Opener WaterGeneral System
1 x 818, DI Resin Refill Bag 16oz (good for up to three refills)
1 x 285, Big Blue SED2005BB 20" Sediment filter WH25 WH250 WH2201
1 x DM-1, Inline Dual TDS monitor (meter) for RO DI System DM1
1 x 741-38, Diverter Valve for RO DI Water Systems
2 x Optional 5th or 6th Stage upgrade inline DI filter(color change)
1 x 1st stage SF05 sediment filter (replace every 6-12 months)
1 x Special, Single Stage Housing Bracket Shell Connection Kit
1 x 532bpg, PAE RO water pressure tank blue bladder gauge valve 4G
1 x B2010, 20" Big Blue Filter Housing Cartridge WH20 WH25 WH250
1 x AQF-600-105, Flow Meter Panel Mount 1/2" MPT
1 x Value Pack- Entire 3 Years of Replacement Filters Bundle RD322
2 x 3rd stage C10 carbon block filter (replace every 6-12 months)
1 x Value Pack- Entire 3 Years of Replacement Filters Bundle AR150P
1 x FM-8100T, DigiFlow Digital Water Flow Rate Meter 56" cable
3 x Optional: 564 Membrane Filter Housing Wrench Opener
1 x 3150, 5th stage TFC-150 US membrane filter (every 2-3 years)
1 x SV-24DC-38-Brass KSD Solenoid Valve 3/8" brass 24V DC ESO
1 x 5th stage 225 Inline Alkaline filter with clear housing (annual)
1 x 719, Drain Saddle Clamp / Valve
1 x UU Clips Pair Membrane to Filter, 2.5" to 2"
1 x 205 2nd stage solid carbon block filter (replace every 12 month)
1 x B1034, 10" Big Blue Filter Housing Cartridge WH5 WH10 WH1134
1 x 532b, PAE RO Water Storage Pressure Osmosis Tank Container 4G
1 x 399, 4th stage TFC-100 US membrane filter (every 2-3 yrs)
1 x 671C, Replacement UV Lamp Light for 609C (16 Watt)
1 x 1/2" NPT Digiflow Digital Flow Meter count up total Water Gallon
1 x PSW-340 Aquatec Pressure Switch 40 psi shut off 3/8" tubing TSO
1 x 214, Clear Inline Filter Cartridge Empty Case
1 x MKP, Maintenance kit for K5150P K6150P AR150P
1 x 741-14, Diverter Valve for Countertop Water Units

View Cart$1,711.99
Information

Flow meter measurement accuracy:

All meters are built in the same way and use the same formula to calculate the flow rate. There are many situations that affect the accuracy of the measurements. Trying to avoid them would increase the accuracy.

1. If there are air bubbles in the lines. Usually this might occur when using a pump to transfer water.

2. Incidents when the flow of water is too slow or too fast that is out of the measuring range. This meter has a range of 0.45 gpm and 3.7 gpm. If the flow of water is sometimes falls out of range, then it can't be counted or measured.
If you are not able to modify your setup in any way to avoid the effects of inaccuracy. You can apply a correction factor to the measurement. For example, take two to three different measurement to find the correction factor for the total count. Use a container that you can tell it has 1 gallon, 2 gallons, and 5 gallons. Use a stop watch to time how much time it takes for the meter to advance 1 gallon. If it takes 70 seconds to advance 1 gallon, then do the same test again to see if the time is about 70 seconds again. Then do the same test for 2 gallons of water. The time should be about 2 times 70 seconds or 140 seconds. If you do this test few times, and the results are the same that means you have found the correction factor. So, the correction factor in this case is 70 sec/ 60sec = 1.1666. If the meter reads 125 gallons then the actual value is about 125 * 1.1666 = 146 gallons.


Please understand most digital flow meters measures similarly. Industrial grade or commercial grade high accuracy flow meter are hundreds and thousands of dollars. Using a simple correction factor you can achieve higher accuracy regardless of your setup.
Continue
Home  |   Specials  |   Log In  |   Create Account  |   Checkout  |   Shopping Cart