Log In Log In  |  Checkout   |  31 item(s)
1 x 6th Stage pn215 Refillable inline DI filter (color change)
1 x 532w, PAE RO Storage Pressure Osmosis Water Tank Container 4G
1 x 4042-K Male Elbow Fitting Compression type(membrane housing use)
1 x CBV-38, Tank Ball Valve to 3/8 tubing
1 x FPK11, High Quality Fitting and Connector 1/4" (Value-Pack)
1 x 3rd stage C10 carbon block filter (replace every 6-12 months)
1 x Optional 566 Filter Housing Wrench Case Opener KoolerMax System
1 x 532b, PAE RO Water Storage Pressure Osmosis Tank Container 4G
1 x FPK, 6 pcs Fitting Pack Union Connector 1/4" quarter inch
1 x Wrench 2 pcs 566 Standard Filter Housing Opener Double Better
1 x Optional: 564 Membrane Filter Housing Wrench Opener
1 x KM701C, Special Koolermax Filter Housing Canister Casing 1/4 FPT
1 x CKV0402, Blue color Elbow Check Valve Elbow Type
1 x MKP, Maintenance kit for K5150P K6150P AR150P
1 x Optional 225UP 5th stage Inline Alkaline upgrade(includes media)
1 x 2542-K, Female Connector 1/4 OD 1/8 FNPT Compression Fitting
1 x 5th or 6th Stage IC21 inline carbon filter (every 6 to 12 mons)
1 x FPK, 6 pcs Fitting Pack Union Connector 3/8 x 1/4 inch
1 x 6044-combo Compression Type Fitting Elbow and Tee fitting
1 x Optional: 566 Filter Housing Wrench Opener WaterGeneral System
1 x 752, DC Booster Pump w/ Transformer
1 x 4044-K qty 2 Male Elbow Fitting Compression type 1/4"
1 x DB40, DI Resin Refill Bag for DI210, RD322
1 x 288, CB1010BB Big Blue Carbon Block Filter 20K-50K gal 10"
1 x B1034, 10" Big Blue Filter Housing Cartridge WH5 WH10 WH1134
1 x 581, Ice Maker Hookup Kit Connect RO water to Fridge Ice Maker
1 x 7044-K Union Tee Connector Fitting Compression type 1/4"
1 x 4th stage TFC150 US membrane filter (every 2-3 yrs)M150 P/N3150
1 x 1044-K Male Connector 1/4 OD x 1/4 NPT Compression Fitting
1 x CBV-0404, Tank Ball Valve to 1/4 tubing *standard RO tank size*
1 x 4064K Male Connector Elbow 3/8 OD Compression Fitting 1/4 NPT

View Cart$562.34
Specials Log InCreate Account Checkout  Shopping Cart31 item(s)
1 x 6th Stage pn215 Refillable inline DI filter (color change)
1 x 532w, PAE RO Storage Pressure Osmosis Water Tank Container 4G
1 x 4042-K Male Elbow Fitting Compression type(membrane housing use)
1 x CBV-38, Tank Ball Valve to 3/8 tubing
1 x FPK11, High Quality Fitting and Connector 1/4" (Value-Pack)
1 x 3rd stage C10 carbon block filter (replace every 6-12 months)
1 x Optional 566 Filter Housing Wrench Case Opener KoolerMax System
1 x 532b, PAE RO Water Storage Pressure Osmosis Tank Container 4G
1 x FPK, 6 pcs Fitting Pack Union Connector 1/4" quarter inch
1 x Wrench 2 pcs 566 Standard Filter Housing Opener Double Better
1 x Optional: 564 Membrane Filter Housing Wrench Opener
1 x KM701C, Special Koolermax Filter Housing Canister Casing 1/4 FPT
1 x CKV0402, Blue color Elbow Check Valve Elbow Type
1 x MKP, Maintenance kit for K5150P K6150P AR150P
1 x Optional 225UP 5th stage Inline Alkaline upgrade(includes media)
1 x 2542-K, Female Connector 1/4 OD 1/8 FNPT Compression Fitting
1 x 5th or 6th Stage IC21 inline carbon filter (every 6 to 12 mons)
1 x FPK, 6 pcs Fitting Pack Union Connector 3/8 x 1/4 inch
1 x 6044-combo Compression Type Fitting Elbow and Tee fitting
1 x Optional: 566 Filter Housing Wrench Opener WaterGeneral System
1 x 752, DC Booster Pump w/ Transformer
1 x 4044-K qty 2 Male Elbow Fitting Compression type 1/4"
1 x DB40, DI Resin Refill Bag for DI210, RD322
1 x 288, CB1010BB Big Blue Carbon Block Filter 20K-50K gal 10"
1 x B1034, 10" Big Blue Filter Housing Cartridge WH5 WH10 WH1134
1 x 581, Ice Maker Hookup Kit Connect RO water to Fridge Ice Maker
1 x 7044-K Union Tee Connector Fitting Compression type 1/4"
1 x 4th stage TFC150 US membrane filter (every 2-3 yrs)M150 P/N3150
1 x 1044-K Male Connector 1/4 OD x 1/4 NPT Compression Fitting
1 x CBV-0404, Tank Ball Valve to 1/4 tubing *standard RO tank size*
1 x 4064K Male Connector Elbow 3/8 OD Compression Fitting 1/4 NPT

View Cart$562.34
Information

Flow meter measurement accuracy:

All meters are built in the same way and use the same formula to calculate the flow rate. There are many situations that affect the accuracy of the measurements. Trying to avoid them would increase the accuracy.

1. If there are air bubbles in the lines. Usually this might occur when using a pump to transfer water.

2. Incidents when the flow of water is too slow or too fast that is out of the measuring range. This meter has a range of 0.45 gpm and 3.7 gpm. If the flow of water is sometimes falls out of range, then it can't be counted or measured.
If you are not able to modify your setup in any way to avoid the effects of inaccuracy. You can apply a correction factor to the measurement. For example, take two to three different measurement to find the correction factor for the total count. Use a container that you can tell it has 1 gallon, 2 gallons, and 5 gallons. Use a stop watch to time how much time it takes for the meter to advance 1 gallon. If it takes 70 seconds to advance 1 gallon, then do the same test again to see if the time is about 70 seconds again. Then do the same test for 2 gallons of water. The time should be about 2 times 70 seconds or 140 seconds. If you do this test few times, and the results are the same that means you have found the correction factor. So, the correction factor in this case is 70 sec/ 60sec = 1.1666. If the meter reads 125 gallons then the actual value is about 125 * 1.1666 = 146 gallons.


Please understand most digital flow meters measures similarly. Industrial grade or commercial grade high accuracy flow meter are hundreds and thousands of dollars. Using a simple correction factor you can achieve higher accuracy regardless of your setup.