Log In Log In  |  Checkout   |  33 item(s)
1 x KM701, Special Koolermax Filter Housing Canister Casing 1/4 FPT
1 x KM701C, Special Koolermax Filter Housing Canister Casing 1/4 FPT
1 x *Discontinued* RO155C
1 x PSW-350, Pressure Switch for RO Booster Pump 1/4" TSO
1 x 565, Digital Pressure Gauge Tester Monitor
3 x 532w, PAE RO Storage Pressure Osmosis Water Tank Container 4G
1 x 701C, FHC1014 Filter Housing Chamber Casing Clear Color 1/4 FPT
1 x UU Clips Pair from Bracket to Membrane Filter
1 x 531, PAE RO Storage Pressure Osmosis Water Tank Container 3G
1 x 3rd stage C10 carbon block filter (replace every 6-12 months)
1 x Wrench 2 pcs 566 Standard Filter Housing Opener Double Better
1 x 2nd stage C10 carbon block filter (replace every 6-12 months)
1 x Optional: 564 Membrane Filter Housing Wrench Opener
2 x MK550, Maintenance kit for RO585, RD102, RD106, RO6, K5, K6
1 x 5th or 6th Stage IC21 inline carbon filter (every 6 to 12 mons)
1 x 1st stage SF05 sediment filter (replace every 6-12 months)
1 x Annual Filter Kit Koolermax Series KPAK-4 Sediment Carbon Block
1 x 213, 5th or 6th stage inline carbon filter (replace in 12 mons)
1 x UU Clips Pair Membrane to Membrane, 2.5" to 2.5"
1 x Y3414BR, Garden Hose Y Adapter Shutoff Valve Brass Construction
1 x 578b, TDS-3 Battery Batteries for #578 TDS Water Quality Meter
1 x .K6150PNTF, KoolerMax K6150P RO System Shell without tank faucet
1 x .K6150P, KoolerMax 150GPD 6 Stage RO System w/ Booster Pump
1 x PSW-260 Aquatec Pressure Switch 60 psi shut off 1/4" tubing TSO
1 x BUNDLE PACK Annual Filter Kit FK4 WaterGeneral 585 106 (4 ITEMS)
1 x FV-15, Bobby Float Valve Top Mount RM292P-N UNS CEL NSF USA
1 x 205 2nd stage solid carbon block filter (replace every 12 month)
1 x Optional 5th or 6th Stage upgrade inline DI filter(color change)
1 x 701, FH1014 Filter Housing Chamber Casing White Color 1/4 FPT
1 x 205, 3rd stage solid carbon block filter (replace every 12month)

View Cart$1,403.00
Specials Log InCreate Account Checkout  Shopping Cart33 item(s)
1 x KM701, Special Koolermax Filter Housing Canister Casing 1/4 FPT
1 x KM701C, Special Koolermax Filter Housing Canister Casing 1/4 FPT
1 x *Discontinued* RO155C
1 x PSW-350, Pressure Switch for RO Booster Pump 1/4" TSO
1 x 565, Digital Pressure Gauge Tester Monitor
3 x 532w, PAE RO Storage Pressure Osmosis Water Tank Container 4G
1 x 701C, FHC1014 Filter Housing Chamber Casing Clear Color 1/4 FPT
1 x UU Clips Pair from Bracket to Membrane Filter
1 x 531, PAE RO Storage Pressure Osmosis Water Tank Container 3G
1 x 3rd stage C10 carbon block filter (replace every 6-12 months)
1 x Wrench 2 pcs 566 Standard Filter Housing Opener Double Better
1 x 2nd stage C10 carbon block filter (replace every 6-12 months)
1 x Optional: 564 Membrane Filter Housing Wrench Opener
2 x MK550, Maintenance kit for RO585, RD102, RD106, RO6, K5, K6
1 x 5th or 6th Stage IC21 inline carbon filter (every 6 to 12 mons)
1 x 1st stage SF05 sediment filter (replace every 6-12 months)
1 x Annual Filter Kit Koolermax Series KPAK-4 Sediment Carbon Block
1 x 213, 5th or 6th stage inline carbon filter (replace in 12 mons)
1 x UU Clips Pair Membrane to Membrane, 2.5" to 2.5"
1 x Y3414BR, Garden Hose Y Adapter Shutoff Valve Brass Construction
1 x 578b, TDS-3 Battery Batteries for #578 TDS Water Quality Meter
1 x .K6150PNTF, KoolerMax K6150P RO System Shell without tank faucet
1 x .K6150P, KoolerMax 150GPD 6 Stage RO System w/ Booster Pump
1 x PSW-260 Aquatec Pressure Switch 60 psi shut off 1/4" tubing TSO
1 x BUNDLE PACK Annual Filter Kit FK4 WaterGeneral 585 106 (4 ITEMS)
1 x FV-15, Bobby Float Valve Top Mount RM292P-N UNS CEL NSF USA
1 x 205 2nd stage solid carbon block filter (replace every 12 month)
1 x Optional 5th or 6th Stage upgrade inline DI filter(color change)
1 x 701, FH1014 Filter Housing Chamber Casing White Color 1/4 FPT
1 x 205, 3rd stage solid carbon block filter (replace every 12month)

View Cart$1,403.00
Information

Flow meter measurement accuracy:

All meters are built in the same way and use the same formula to calculate the flow rate. There are many situations that affect the accuracy of the measurements. Trying to avoid them would increase the accuracy.

1. If there are air bubbles in the lines. Usually this might occur when using a pump to transfer water.

2. Incidents when the flow of water is too slow or too fast that is out of the measuring range. This meter has a range of 0.45 gpm and 3.7 gpm. If the flow of water is sometimes falls out of range, then it can't be counted or measured.
If you are not able to modify your setup in any way to avoid the effects of inaccuracy. You can apply a correction factor to the measurement. For example, take two to three different measurement to find the correction factor for the total count. Use a container that you can tell it has 1 gallon, 2 gallons, and 5 gallons. Use a stop watch to time how much time it takes for the meter to advance 1 gallon. If it takes 70 seconds to advance 1 gallon, then do the same test again to see if the time is about 70 seconds again. Then do the same test for 2 gallons of water. The time should be about 2 times 70 seconds or 140 seconds. If you do this test few times, and the results are the same that means you have found the correction factor. So, the correction factor in this case is 70 sec/ 60sec = 1.1666. If the meter reads 125 gallons then the actual value is about 125 * 1.1666 = 146 gallons.


Please understand most digital flow meters measures similarly. Industrial grade or commercial grade high accuracy flow meter are hundreds and thousands of dollars. Using a simple correction factor you can achieve higher accuracy regardless of your setup.
Continue