Log In Log In  |  Checkout   |  29 item(s)
1 x CKV0402, Blue color Elbow Check Valve Elbow Type
1 x Optional 225UP 5th stage Inline Alkaline upgrade(includes media)
1 x 3150, 4th stage TFC-150 US membrane filter (every 2-3 yrs)
1 x 4044-K Male Elbow Fitting Compression type 1/4" OD 1/4" NPT
1 x HK120-PUMP KoolerMax Aeroponics Hydroponics System Booster Pump
2 x Wrench 2 pcs 566 Standard Filter Housing Opener Double Better
2 x Optional: 564 Membrane Filter Housing Wrench Opener
1 x Annual Filter Kit Koolermax Series KPAK-4 Sediment Carbon Block
1 x 1044-K Male Connector 1/4 OD x 1/4 NPT Compression Fitting
1 x Optional: 566 Filter Housing Wrench Opener WaterGeneral System
1 x .SW-1C COUNTERTOP WATER FILTER SYSTEM (CLEAR HOUSING)
1 x MK8002, Maintenance kit for double membrane system RD322 RO260
1 x 4064K Male Connector Elbow 3/8 OD Compression Fitting 1/4 NPT
1 x 818, DI Resin Refill Bag 16oz (good for up to three refills)
1 x 215, 5th or 6th Stage Refillable inline DI filter (color change)
1 x MKP, Maintenance kit for K5150P K6150P AR150P
1 x 2.CB2010, 2nd stage carbon block filter 20" inch for RD322 RO260
1 x FPK11, High Quality Fitting and Connector 1/4" (Value-Pack)
1 x OPTIONAL: 567 Filter Housing Wrench Case Opener WHOLE HOUSE WH
1 x 3rd stage C10 carbon block filter (replace every 6-12 months)
1 x 752, DC Booster Pump w/ Transformer
1 x 532w, PAE RO Storage Pressure Osmosis Water Tank Container 4G
1 x 532b, PAE RO Water Storage Pressure Osmosis Tank Container 4G
1 x N-14-1M, Nipple Fitting connector between standard RO housing
1 x 7044-K Union Tee Connector Fitting Compression type 1/4"
1 x B2012, 20" Long Slim Filter Cartridge Housing RO260 RD322
1 x 2nd stage C10 carbon block filter (replace every 6-12 months)

View Cart$887.90
Specials Log InCreate Account Checkout  Shopping Cart29 item(s)
1 x CKV0402, Blue color Elbow Check Valve Elbow Type
1 x Optional 225UP 5th stage Inline Alkaline upgrade(includes media)
1 x 3150, 4th stage TFC-150 US membrane filter (every 2-3 yrs)
1 x 4044-K Male Elbow Fitting Compression type 1/4" OD 1/4" NPT
1 x HK120-PUMP KoolerMax Aeroponics Hydroponics System Booster Pump
2 x Wrench 2 pcs 566 Standard Filter Housing Opener Double Better
2 x Optional: 564 Membrane Filter Housing Wrench Opener
1 x Annual Filter Kit Koolermax Series KPAK-4 Sediment Carbon Block
1 x 1044-K Male Connector 1/4 OD x 1/4 NPT Compression Fitting
1 x Optional: 566 Filter Housing Wrench Opener WaterGeneral System
1 x .SW-1C COUNTERTOP WATER FILTER SYSTEM (CLEAR HOUSING)
1 x MK8002, Maintenance kit for double membrane system RD322 RO260
1 x 4064K Male Connector Elbow 3/8 OD Compression Fitting 1/4 NPT
1 x 818, DI Resin Refill Bag 16oz (good for up to three refills)
1 x 215, 5th or 6th Stage Refillable inline DI filter (color change)
1 x MKP, Maintenance kit for K5150P K6150P AR150P
1 x 2.CB2010, 2nd stage carbon block filter 20" inch for RD322 RO260
1 x FPK11, High Quality Fitting and Connector 1/4" (Value-Pack)
1 x OPTIONAL: 567 Filter Housing Wrench Case Opener WHOLE HOUSE WH
1 x 3rd stage C10 carbon block filter (replace every 6-12 months)
1 x 752, DC Booster Pump w/ Transformer
1 x 532w, PAE RO Storage Pressure Osmosis Water Tank Container 4G
1 x 532b, PAE RO Water Storage Pressure Osmosis Tank Container 4G
1 x N-14-1M, Nipple Fitting connector between standard RO housing
1 x 7044-K Union Tee Connector Fitting Compression type 1/4"
1 x B2012, 20" Long Slim Filter Cartridge Housing RO260 RD322
1 x 2nd stage C10 carbon block filter (replace every 6-12 months)

View Cart$887.90
Information

Flow meter measurement accuracy:

All meters are built in the same way and use the same formula to calculate the flow rate. There are many situations that affect the accuracy of the measurements. Trying to avoid them would increase the accuracy.

1. If there are air bubbles in the lines. Usually this might occur when using a pump to transfer water.

2. Incidents when the flow of water is too slow or too fast that is out of the measuring range. This meter has a range of 0.45 gpm and 3.7 gpm. If the flow of water is sometimes falls out of range, then it can't be counted or measured.
If you are not able to modify your setup in any way to avoid the effects of inaccuracy. You can apply a correction factor to the measurement. For example, take two to three different measurement to find the correction factor for the total count. Use a container that you can tell it has 1 gallon, 2 gallons, and 5 gallons. Use a stop watch to time how much time it takes for the meter to advance 1 gallon. If it takes 70 seconds to advance 1 gallon, then do the same test again to see if the time is about 70 seconds again. Then do the same test for 2 gallons of water. The time should be about 2 times 70 seconds or 140 seconds. If you do this test few times, and the results are the same that means you have found the correction factor. So, the correction factor in this case is 70 sec/ 60sec = 1.1666. If the meter reads 125 gallons then the actual value is about 125 * 1.1666 = 146 gallons.


Please understand most digital flow meters measures similarly. Industrial grade or commercial grade high accuracy flow meter are hundreds and thousands of dollars. Using a simple correction factor you can achieve higher accuracy regardless of your setup.
Continue
Home  |   Specials  |   Log In  |   Create Account  |   Checkout  |   Shopping Cart