Log In Log In  |  Checkout   |  24 item(s)
1 x FM10, STEEL BRACKET SINGLE HOUSING MOUNTING SYSTEM
1 x 225UP, 5th stage Inline Alkaline upgrade (includes media)
1 x Panel 1" Digiflow 6710M-88TM Digital Flow Meter count up GPM 115
1 x MK550, Maintenance kit for RO585, RD102, RD106, RO6, K5, K6
1 x MK800, Maintenance kit for AR122, AR125, HK120, RD150, RO155
1 x 4042-K Male Elbow Fitting Compression type(membrane housing use)
1 x 214, Clear Inline Filter Cartridge Empty Case
1 x .AR125 Dual Outputs Aquarium & Home Drinking RO Filter System
1 x FRQ300, Flow Restrictor 300ML / min
1 x B1034, 10" Big Blue Filter Housing Cartridge WH5 WH10 WH1134
1 x .RO260 Aquarium 300G REVERSE OSMOSIS AEROPONICS HYDROPONICS RO
1 x PSW-3100 Aquatec Pressure Switch 100 psi shut off 3/8 tubing TSO
1 x WH-20, Whole House Water Treatment Carbon Block Filter System Bi
1 x Optional: 564 Membrane Filter Housing Wrench Opener
1 x NM-5102, HONEYWELL COUNTERTOP WATER FILTER *DISCONTINUED* SW1
1 x PSW-360 Aquatec Pressure Switch 60 psi shut off 3/8" tubing TSO
1 x KM701, Special Koolermax Filter Housing Canister Casing 1/4 FPT
1 x B2012, 20" Long Slim Filter Cartridge Housing RO260 RD322
1 x 285, Big Blue SED2005BB 20" Sediment filter WH25 WH250 WH2201
1 x CPR-150G, Pressure Regulator with Pressure Gauge (0-125 psi)
1 x EMT-10, Empty Filter Cartridge Casing Housing
1 x 1st stage SF05 sediment filter (replace every 6-12 months)
1 x 818, DI Resin Refill Bag 16oz (good for up to three refills)
1 x 727, Feed Water Adapter 3/8" compression adapter 1/4" inline bal

View Cart$1,057.50
Specials Log InCreate Account Checkout  Shopping Cart24 item(s)
1 x FM10, STEEL BRACKET SINGLE HOUSING MOUNTING SYSTEM
1 x 225UP, 5th stage Inline Alkaline upgrade (includes media)
1 x Panel 1" Digiflow 6710M-88TM Digital Flow Meter count up GPM 115
1 x MK550, Maintenance kit for RO585, RD102, RD106, RO6, K5, K6
1 x MK800, Maintenance kit for AR122, AR125, HK120, RD150, RO155
1 x 4042-K Male Elbow Fitting Compression type(membrane housing use)
1 x 214, Clear Inline Filter Cartridge Empty Case
1 x .AR125 Dual Outputs Aquarium & Home Drinking RO Filter System
1 x FRQ300, Flow Restrictor 300ML / min
1 x B1034, 10" Big Blue Filter Housing Cartridge WH5 WH10 WH1134
1 x .RO260 Aquarium 300G REVERSE OSMOSIS AEROPONICS HYDROPONICS RO
1 x PSW-3100 Aquatec Pressure Switch 100 psi shut off 3/8 tubing TSO
1 x WH-20, Whole House Water Treatment Carbon Block Filter System Bi
1 x Optional: 564 Membrane Filter Housing Wrench Opener
1 x NM-5102, HONEYWELL COUNTERTOP WATER FILTER *DISCONTINUED* SW1
1 x PSW-360 Aquatec Pressure Switch 60 psi shut off 3/8" tubing TSO
1 x KM701, Special Koolermax Filter Housing Canister Casing 1/4 FPT
1 x B2012, 20" Long Slim Filter Cartridge Housing RO260 RD322
1 x 285, Big Blue SED2005BB 20" Sediment filter WH25 WH250 WH2201
1 x CPR-150G, Pressure Regulator with Pressure Gauge (0-125 psi)
1 x EMT-10, Empty Filter Cartridge Casing Housing
1 x 1st stage SF05 sediment filter (replace every 6-12 months)
1 x 818, DI Resin Refill Bag 16oz (good for up to three refills)
1 x 727, Feed Water Adapter 3/8" compression adapter 1/4" inline bal

View Cart$1,057.50
Information

Flow meter measurement accuracy:

All meters are built in the same way and use the same formula to calculate the flow rate. There are many situations that affect the accuracy of the measurements. Trying to avoid them would increase the accuracy.

1. If there are air bubbles in the lines. Usually this might occur when using a pump to transfer water.

2. Incidents when the flow of water is too slow or too fast that is out of the measuring range. This meter has a range of 0.45 gpm and 3.7 gpm. If the flow of water is sometimes falls out of range, then it can't be counted or measured.
If you are not able to modify your setup in any way to avoid the effects of inaccuracy. You can apply a correction factor to the measurement. For example, take two to three different measurement to find the correction factor for the total count. Use a container that you can tell it has 1 gallon, 2 gallons, and 5 gallons. Use a stop watch to time how much time it takes for the meter to advance 1 gallon. If it takes 70 seconds to advance 1 gallon, then do the same test again to see if the time is about 70 seconds again. Then do the same test for 2 gallons of water. The time should be about 2 times 70 seconds or 140 seconds. If you do this test few times, and the results are the same that means you have found the correction factor. So, the correction factor in this case is 70 sec/ 60sec = 1.1666. If the meter reads 125 gallons then the actual value is about 125 * 1.1666 = 146 gallons.


Please understand most digital flow meters measures similarly. Industrial grade or commercial grade high accuracy flow meter are hundreds and thousands of dollars. Using a simple correction factor you can achieve higher accuracy regardless of your setup.
Continue
Home  |   Specials  |   Log In  |   Create Account  |   Checkout  |   Shopping Cart