Log In Log In  |  Checkout   |  26 item(s)
1 x .AR125NTF KoolerMax AR125 RO System Shell without tank & faucet
1 x 214, Clear Inline Filter Cartridge Empty Case
1 x 1st stage SF05 sediment filter (replace every 6-12 months)
1 x Optional: 566 Filter Housing Wrench Opener WaterGeneral System
1 x Optional 225UP 5th stage Inline Alkaline upgrade(includes media)
1 x FK-BB20M3, Special Big Blue Filter Pack Bundle for WH350 WH-350
1 x 1070, PAE LARGE RO Storage Pressure Tank 14 GALLON 14G
1 x Panel 1" Digiflow 6710M-88TM Digital Flow Meter count up GPM 115
1 x ERP500 Aquatec Permeate Pump Reverse Osmosis RO System USA made
1 x .AR125 Dual Outputs Aquarium & Home Drinking RO Filter System
1 x 701, FH1014 Filter Housing Chamber Casing White Color 1/4 FPT
1 x CP-OR35+701 O-RING FOR WATERGENERAL BOTTOM FILTER HOUSING CASING
1 x Micro 1/4 NPT Digital Flow Meter count up total Water Liter LPM
1 x B2010, 20" Big Blue Filter Housing Cartridge WH20 WH25 WH250
1 x SC227, Specialty Filter Refillable Color Changing DI Filter 20"
1 x 335, 3rd stage TFC 35/45 US membrane filter (every 2-3 yrs)
1 x CKV0402, Blue color Elbow Check Valve Elbow Type
1 x 755, Aquatec Demand Delivery Pump 5851-7E12-J574 Increase Output
1 x B2012, 20" Long Slim Filter Cartridge Housing RO260 RD322
1 x 752set, DC Booster Pump Transformer Solenoid Pressure Switch All
1 x .RD322 Aquarium 260-300 GPD REVERSE OSMOSIS RO+DI WATER SYSTEM
1 x 532w, PAE RO Storage Pressure Osmosis Water Tank Container 4G
1 x 385, 4th stage TFC 75/85 US membrane filter (every 2-3 yrs)
1 x FK-53, Replacement Filter Pack SED2005 CB2010 for RD322 RO260
1 x 201, 1st stage sediment filter (replace every 6-12 months)
1 x Special Filter Kit Koolermax dealer distribution kit

View Cart$1,873.00
Specials Log InCreate Account Checkout  Shopping Cart26 item(s)
1 x .AR125NTF KoolerMax AR125 RO System Shell without tank & faucet
1 x 214, Clear Inline Filter Cartridge Empty Case
1 x 1st stage SF05 sediment filter (replace every 6-12 months)
1 x Optional: 566 Filter Housing Wrench Opener WaterGeneral System
1 x Optional 225UP 5th stage Inline Alkaline upgrade(includes media)
1 x FK-BB20M3, Special Big Blue Filter Pack Bundle for WH350 WH-350
1 x 1070, PAE LARGE RO Storage Pressure Tank 14 GALLON 14G
1 x Panel 1" Digiflow 6710M-88TM Digital Flow Meter count up GPM 115
1 x ERP500 Aquatec Permeate Pump Reverse Osmosis RO System USA made
1 x .AR125 Dual Outputs Aquarium & Home Drinking RO Filter System
1 x 701, FH1014 Filter Housing Chamber Casing White Color 1/4 FPT
1 x CP-OR35+701 O-RING FOR WATERGENERAL BOTTOM FILTER HOUSING CASING
1 x Micro 1/4 NPT Digital Flow Meter count up total Water Liter LPM
1 x B2010, 20" Big Blue Filter Housing Cartridge WH20 WH25 WH250
1 x SC227, Specialty Filter Refillable Color Changing DI Filter 20"
1 x 335, 3rd stage TFC 35/45 US membrane filter (every 2-3 yrs)
1 x CKV0402, Blue color Elbow Check Valve Elbow Type
1 x 755, Aquatec Demand Delivery Pump 5851-7E12-J574 Increase Output
1 x B2012, 20" Long Slim Filter Cartridge Housing RO260 RD322
1 x 752set, DC Booster Pump Transformer Solenoid Pressure Switch All
1 x .RD322 Aquarium 260-300 GPD REVERSE OSMOSIS RO+DI WATER SYSTEM
1 x 532w, PAE RO Storage Pressure Osmosis Water Tank Container 4G
1 x 385, 4th stage TFC 75/85 US membrane filter (every 2-3 yrs)
1 x FK-53, Replacement Filter Pack SED2005 CB2010 for RD322 RO260
1 x 201, 1st stage sediment filter (replace every 6-12 months)
1 x Special Filter Kit Koolermax dealer distribution kit

View Cart$1,873.00
Information

Flow meter measurement accuracy:

All meters are built in the same way and use the same formula to calculate the flow rate. There are many situations that affect the accuracy of the measurements. Trying to avoid them would increase the accuracy.

1. If there are air bubbles in the lines. Usually this might occur when using a pump to transfer water.

2. Incidents when the flow of water is too slow or too fast that is out of the measuring range. This meter has a range of 0.45 gpm and 3.7 gpm. If the flow of water is sometimes falls out of range, then it can't be counted or measured.
If you are not able to modify your setup in any way to avoid the effects of inaccuracy. You can apply a correction factor to the measurement. For example, take two to three different measurement to find the correction factor for the total count. Use a container that you can tell it has 1 gallon, 2 gallons, and 5 gallons. Use a stop watch to time how much time it takes for the meter to advance 1 gallon. If it takes 70 seconds to advance 1 gallon, then do the same test again to see if the time is about 70 seconds again. Then do the same test for 2 gallons of water. The time should be about 2 times 70 seconds or 140 seconds. If you do this test few times, and the results are the same that means you have found the correction factor. So, the correction factor in this case is 70 sec/ 60sec = 1.1666. If the meter reads 125 gallons then the actual value is about 125 * 1.1666 = 146 gallons.


Please understand most digital flow meters measures similarly. Industrial grade or commercial grade high accuracy flow meter are hundreds and thousands of dollars. Using a simple correction factor you can achieve higher accuracy regardless of your setup.
Continue
Home  |   Specials  |   Log In  |   Create Account  |   Checkout  |   Shopping Cart