Log In Log In  |  Checkout   |  25 item(s)
1 x KF750, Elite Series: Polish Chrome Drinking Water Faucet
1 x MK800, Maintenance kit for AR122, AR125, HK120, RD150, RO155
1 x 213, 5th or 6th stage inline carbon filter (replace in 12 mons)
1 x MK225, Maintenance kit for Honeywell RO9100 Filtercold RO5 AV180
1 x PSW-340 Aquatec Pressure Switch 40 psi shut off 3/8" tubing TSO
1 x ERP1000 Aquatec Permeate Pump Reverse Osmosis RO System USA made
2 x 205, 3rd stage solid carbon block filter (replace every 12month)
1 x TMR-AQT-2A, Transformer Power Supply Aquatec TACS114-48 for 8800
1 x 1st stage SF05 sediment filter (replace every 6-12 months)
1 x AMTU-0404 Male Tee Union Connector NPT Thread 1/4" Quick Connect
1 x 4th stage TFC150 US membrane filter (every 2-3 yrs)M150 P/N3150
1 x 324, 4th stage TFC-24 US membrane filter (replace every 2-3 yrs)
1 x 755, Aquatec Demand Delivery Pump 5851-7E12-J574 Increase Output
2 x OPTIONAL: 567 Filter Housing Wrench Case Opener WHOLE HOUSE WH
1 x 5th stage 225 Inline Alkaline filter with clear housing (annual)
1 x PSW-3100 Aquatec Pressure Switch 100 psi shut off 3/8 tubing TSO
1 x Wrench 2 pcs 566 Standard Filter Housing Opener Double Better
1 x 4044-K qty 2 Male Elbow Fitting Compression type 1/4"
1 x Value Pack- Entire 3 Years of Replacement Filters Bundle AR125
1 x 205 2nd stage solid carbon block filter (replace every 12 month)
1 x 201, 1st stage sediment filter (replace every 6-12 months)
1 x ACT-820-JG Aquatec Pulsation Dampener Accumulator Pressure Tank
1 x CP-OR35+701 O-RING FOR WATERGENERAL BOTTOM FILTER HOUSING CASING

View Cart$821.00
Specials Log InCreate Account Checkout  Shopping Cart25 item(s)
1 x KF750, Elite Series: Polish Chrome Drinking Water Faucet
1 x MK800, Maintenance kit for AR122, AR125, HK120, RD150, RO155
1 x 213, 5th or 6th stage inline carbon filter (replace in 12 mons)
1 x MK225, Maintenance kit for Honeywell RO9100 Filtercold RO5 AV180
1 x PSW-340 Aquatec Pressure Switch 40 psi shut off 3/8" tubing TSO
1 x ERP1000 Aquatec Permeate Pump Reverse Osmosis RO System USA made
2 x 205, 3rd stage solid carbon block filter (replace every 12month)
1 x TMR-AQT-2A, Transformer Power Supply Aquatec TACS114-48 for 8800
1 x 1st stage SF05 sediment filter (replace every 6-12 months)
1 x AMTU-0404 Male Tee Union Connector NPT Thread 1/4" Quick Connect
1 x 4th stage TFC150 US membrane filter (every 2-3 yrs)M150 P/N3150
1 x 324, 4th stage TFC-24 US membrane filter (replace every 2-3 yrs)
1 x 755, Aquatec Demand Delivery Pump 5851-7E12-J574 Increase Output
2 x OPTIONAL: 567 Filter Housing Wrench Case Opener WHOLE HOUSE WH
1 x 5th stage 225 Inline Alkaline filter with clear housing (annual)
1 x PSW-3100 Aquatec Pressure Switch 100 psi shut off 3/8 tubing TSO
1 x Wrench 2 pcs 566 Standard Filter Housing Opener Double Better
1 x 4044-K qty 2 Male Elbow Fitting Compression type 1/4"
1 x Value Pack- Entire 3 Years of Replacement Filters Bundle AR125
1 x 205 2nd stage solid carbon block filter (replace every 12 month)
1 x 201, 1st stage sediment filter (replace every 6-12 months)
1 x ACT-820-JG Aquatec Pulsation Dampener Accumulator Pressure Tank
1 x CP-OR35+701 O-RING FOR WATERGENERAL BOTTOM FILTER HOUSING CASING

View Cart$821.00
Information

Flow meter measurement accuracy:

All meters are built in the same way and use the same formula to calculate the flow rate. There are many situations that affect the accuracy of the measurements. Trying to avoid them would increase the accuracy.

1. If there are air bubbles in the lines. Usually this might occur when using a pump to transfer water.

2. Incidents when the flow of water is too slow or too fast that is out of the measuring range. This meter has a range of 0.45 gpm and 3.7 gpm. If the flow of water is sometimes falls out of range, then it can't be counted or measured.
If you are not able to modify your setup in any way to avoid the effects of inaccuracy. You can apply a correction factor to the measurement. For example, take two to three different measurement to find the correction factor for the total count. Use a container that you can tell it has 1 gallon, 2 gallons, and 5 gallons. Use a stop watch to time how much time it takes for the meter to advance 1 gallon. If it takes 70 seconds to advance 1 gallon, then do the same test again to see if the time is about 70 seconds again. Then do the same test for 2 gallons of water. The time should be about 2 times 70 seconds or 140 seconds. If you do this test few times, and the results are the same that means you have found the correction factor. So, the correction factor in this case is 70 sec/ 60sec = 1.1666. If the meter reads 125 gallons then the actual value is about 125 * 1.1666 = 146 gallons.


Please understand most digital flow meters measures similarly. Industrial grade or commercial grade high accuracy flow meter are hundreds and thousands of dollars. Using a simple correction factor you can achieve higher accuracy regardless of your setup.
Continue
Home  |   Specials  |   Log In  |   Create Account  |   Checkout  |   Shopping Cart