Log In Log In  |  Checkout   |  42 item(s)
1 x TMR-AQT-68, Transformer Power Supply Aquatec TACS114-19EP for 68
1 x 350UP, Upgrade Kit TFC50 gal/day (includes US membrane filter)
1 x B2010, 20" Big Blue Filter Housing Cartridge WH20 WH25 WH250
1 x WH1134 Whole House Restaurant Filter System Sediment Carbon Big
1 x WH-10, Whole House Water Treatment Carbon Filter System 10" Big
1 x 7044-K Union Tee Connector Fitting Compression type 1/4"
1 x 5th or 6th Stage IC21 inline carbon filter (every 6 to 12 mons)
1 x 4042-K Male Elbow Fitting Compression type(membrane housing use)
1 x 2542-K, Female Connector 1/4 OD 1/8 FNPT Compression Fitting
1 x CDP8800, AQUATEC CDP8852-2J03-B424 Booster Pump Only Fitting
1 x SV-110AC-14, Solenoid Valve 1/4" plastic 110VAC ESO
1 x 4044-K qty 2 Male Elbow Fitting Compression type 1/4"
1 x TMR-AQT-2A, Transformer Power Supply Aquatec TACS114-48 for 8800
2 x 205, 3rd stage solid carbon block filter (replace every 12month)
1 x TMR-DC-2412, Transformer Power Supply for #752 Booster Pump
1 x 2.CB2010, 2nd stage carbon block filter 20" inch for RD322 RO260
1 x DB40, DI Resin Refill Bag for DI210, RD322
1 x SET68, AQUATEC 6840 AC Pump Set Solenoid ESO Pressure Switch SET
1 x MK550, Maintenance kit for RO585, RD102, RD106, RO6, K5, K6
1 x MK800, Maintenance kit for AR122, AR125, HK120, RD150, RO155
1 x 204, 2nd stage GAC filter (replace every 6-12 months)
1 x OPTIONAL: 567 Filter Housing Wrench Case Opener WHOLE HOUSE WH
1 x KM701, Special Koolermax Filter Housing Canister Casing 1/4 FPT
1 x MK8002, Maintenance kit for double membrane system RD322 RO260
1 x CP-OR35+701 O-RING FOR WATERGENERAL BOTTOM FILTER HOUSING CASING
1 x Wrench 2 pcs 566 Standard Filter Housing Opener Double Better
1 x TMR-220V-2A Aquatec TACS234-48 Transformer Power Supply EuroPlug
1 x 285, Big Blue SED2005BB 20" Sediment filter WH25 WH250 WH2201
1 x SV-24AC-14, Solenoid Valve for Aquatec pump only 1/4" 24VAC ESO
1 x 755, Aquatec Demand Delivery Pump 5851-7E12-J574 Increase Output
1 x 205 2nd stage solid carbon block filter (replace every 12 month)
1 x CKV0402, Blue color Elbow Check Valve Elbow Type
1 x SC227, Specialty Filter Refillable Color Changing DI Filter 20"
1 x PSW-380 Aquatec Pressure Switch 80 psi shut off 3/8" tubing TSO
1 x FPK11, High Quality Fitting and Connector 1/4" (Value-Pack)
1 x 3rd stage C10 carbon block filter (replace every 6-12 months)
1 x WSACF-150T, Whole House Water Treatment ACF-150T
1 x 3.CB2010, 3rd stage carbon block filter 20" inch for RD322 RO260
1 x 532w, PAE RO Storage Pressure Osmosis Water Tank Container 4G
1 x SET8855 Aquatec 5853 Booster Pump Assembly for Aeroponics System
1 x ACT-820-JG Aquatec Pulsation Dampener Accumulator Pressure Tank

View Cart$4,019.90
Specials Log InCreate Account Checkout  Shopping Cart42 item(s)
1 x TMR-AQT-68, Transformer Power Supply Aquatec TACS114-19EP for 68
1 x 350UP, Upgrade Kit TFC50 gal/day (includes US membrane filter)
1 x B2010, 20" Big Blue Filter Housing Cartridge WH20 WH25 WH250
1 x WH1134 Whole House Restaurant Filter System Sediment Carbon Big
1 x WH-10, Whole House Water Treatment Carbon Filter System 10" Big
1 x 7044-K Union Tee Connector Fitting Compression type 1/4"
1 x 5th or 6th Stage IC21 inline carbon filter (every 6 to 12 mons)
1 x 4042-K Male Elbow Fitting Compression type(membrane housing use)
1 x 2542-K, Female Connector 1/4 OD 1/8 FNPT Compression Fitting
1 x CDP8800, AQUATEC CDP8852-2J03-B424 Booster Pump Only Fitting
1 x SV-110AC-14, Solenoid Valve 1/4" plastic 110VAC ESO
1 x 4044-K qty 2 Male Elbow Fitting Compression type 1/4"
1 x TMR-AQT-2A, Transformer Power Supply Aquatec TACS114-48 for 8800
2 x 205, 3rd stage solid carbon block filter (replace every 12month)
1 x TMR-DC-2412, Transformer Power Supply for #752 Booster Pump
1 x 2.CB2010, 2nd stage carbon block filter 20" inch for RD322 RO260
1 x DB40, DI Resin Refill Bag for DI210, RD322
1 x SET68, AQUATEC 6840 AC Pump Set Solenoid ESO Pressure Switch SET
1 x MK550, Maintenance kit for RO585, RD102, RD106, RO6, K5, K6
1 x MK800, Maintenance kit for AR122, AR125, HK120, RD150, RO155
1 x 204, 2nd stage GAC filter (replace every 6-12 months)
1 x OPTIONAL: 567 Filter Housing Wrench Case Opener WHOLE HOUSE WH
1 x KM701, Special Koolermax Filter Housing Canister Casing 1/4 FPT
1 x MK8002, Maintenance kit for double membrane system RD322 RO260
1 x CP-OR35+701 O-RING FOR WATERGENERAL BOTTOM FILTER HOUSING CASING
1 x Wrench 2 pcs 566 Standard Filter Housing Opener Double Better
1 x TMR-220V-2A Aquatec TACS234-48 Transformer Power Supply EuroPlug
1 x 285, Big Blue SED2005BB 20" Sediment filter WH25 WH250 WH2201
1 x SV-24AC-14, Solenoid Valve for Aquatec pump only 1/4" 24VAC ESO
1 x 755, Aquatec Demand Delivery Pump 5851-7E12-J574 Increase Output
1 x 205 2nd stage solid carbon block filter (replace every 12 month)
1 x CKV0402, Blue color Elbow Check Valve Elbow Type
1 x SC227, Specialty Filter Refillable Color Changing DI Filter 20"
1 x PSW-380 Aquatec Pressure Switch 80 psi shut off 3/8" tubing TSO
1 x FPK11, High Quality Fitting and Connector 1/4" (Value-Pack)
1 x 3rd stage C10 carbon block filter (replace every 6-12 months)
1 x WSACF-150T, Whole House Water Treatment ACF-150T
1 x 3.CB2010, 3rd stage carbon block filter 20" inch for RD322 RO260
1 x 532w, PAE RO Storage Pressure Osmosis Water Tank Container 4G
1 x SET8855 Aquatec 5853 Booster Pump Assembly for Aeroponics System
1 x ACT-820-JG Aquatec Pulsation Dampener Accumulator Pressure Tank

View Cart$4,019.90
Information

Flow meter measurement accuracy:

All meters are built in the same way and use the same formula to calculate the flow rate. There are many situations that affect the accuracy of the measurements. Trying to avoid them would increase the accuracy.

1. If there are air bubbles in the lines. Usually this might occur when using a pump to transfer water.

2. Incidents when the flow of water is too slow or too fast that is out of the measuring range. This meter has a range of 0.45 gpm and 3.7 gpm. If the flow of water is sometimes falls out of range, then it can't be counted or measured.
If you are not able to modify your setup in any way to avoid the effects of inaccuracy. You can apply a correction factor to the measurement. For example, take two to three different measurement to find the correction factor for the total count. Use a container that you can tell it has 1 gallon, 2 gallons, and 5 gallons. Use a stop watch to time how much time it takes for the meter to advance 1 gallon. If it takes 70 seconds to advance 1 gallon, then do the same test again to see if the time is about 70 seconds again. Then do the same test for 2 gallons of water. The time should be about 2 times 70 seconds or 140 seconds. If you do this test few times, and the results are the same that means you have found the correction factor. So, the correction factor in this case is 70 sec/ 60sec = 1.1666. If the meter reads 125 gallons then the actual value is about 125 * 1.1666 = 146 gallons.


Please understand most digital flow meters measures similarly. Industrial grade or commercial grade high accuracy flow meter are hundreds and thousands of dollars. Using a simple correction factor you can achieve higher accuracy regardless of your setup.
Continue
Home  |   Specials  |   Log In  |   Create Account  |   Checkout  |   Shopping Cart