Log In Log In  |  Checkout   |  49 item(s)
1 x MK800, Maintenance kit for AR122, AR125, HK120, RD150, RO155
1 x KM701C, Special Koolermax Filter Housing Canister Casing 1/4 FPT
1 x 4064K Male Connector Elbow 3/8 OD Compression Fitting 1/4 NPT
1 x 532b, PAE RO Water Storage Pressure Osmosis Tank Container 4G
2 x 201, 1st stage sediment filter (replace every 6-12 months)
1 x 733, Built-in Pressure Gauge 0 to 150 psi for Koolermax RO syste
1 x 205 2nd stage solid carbon block filter (replace every 12 month)
1 x Value Pack- Entire 3 Years of Replacement Filters Bundle RO155
1 x SV-24DC-38-Brass KSD Solenoid Valve 3/8" brass 24V DC ESO
1 x TMR-DC-1212, Transformer Power Supply for Delivery Demand Pump
1 x 7044-K Union Tee Connector Fitting Compression type 1/4"
1 x O-RING RINGS FOR WH20 WHOLE HOUSE SYSTEM HOUSING BIG BLUE 20"
1 x Optional 5th or 6th Stage upgrade inline DI filter(color change)
2 x PSW-260 Aquatec Pressure Switch 60 psi shut off 1/4" tubing TSO
1 x PSW-360 Aquatec Pressure Switch 60 psi shut off 3/8" tubing TSO
1 x KF320UP, SUBSTITUTE/Upgrade Faucet BRUSHED NICKEL STAINLESS STEE
1 x FPK11, High Quality Fitting and Connector 1/4" (Value-Pack)
1 x 6044-combo Compression Type Fitting Elbow and Tee fitting
2 x DB40, DI Resin Refill Bag for DI210, RD322
1 x PSW-240 Aquatec Pressure Switch 40 psi shut off 1/4" tubing TSO
1 x MK8002, Maintenance kit for double membrane system RD322 RO260
1 x Wrench 2 pcs 566 Standard Filter Housing Opener Double Better
1 x 4th stage TFC150 US membrane filter (every 2-3 yrs)M150 P/N3150
1 x 316, 2nd stage CTA 16 US Membrane filter
1 x B2010, 20" Big Blue Filter Housing Cartridge WH20 WH25 WH250
1 x .AR150PNTF, KoolerMax AR150P RO System Shell without tank faucet
1 x ACT-820-JG Aquatec Pulsation Dampener Accumulator Pressure Tank
1 x PSW-340 Aquatec Pressure Switch 40 psi shut off 3/8" tubing TSO
1 x AMTU-0404 Male Tee Union Connector NPT Thread 1/4" Quick Connect
1 x Value Pack- Entire 3 Years of Replacement Filters Bundle RD150
1 x Special, Output Conversion Kit Convert from 1/4" to 3/8"
1 x 727, Feed Water Adapter 3/8" compression adapter 1/4" inline bal
1 x 701, FH1014 Filter Housing Chamber Casing White Color 1/4 FPT
1 x SV-24AC-14, Solenoid Valve for Aquatec pump only 1/4" 24VAC ESO
1 x CP-OR35+701 O-RING FOR WATERGENERAL BOTTOM FILTER HOUSING CASING
1 x 6044-K Tee Fitting Compression Type 1/4"OD 1/4" NPT
1 x 752set, DC Booster Pump Transformer Solenoid Pressure Switch All
1 x *Discontinued* RD106
1 x 5th or 6th Stage IC21 inline carbon filter (every 6 to 12 mons)
1 x 399, 4th stage TFC-100 US membrane filter (every 2-3 yrs)
1 x WH-250, Whole House Water Treatment Sediment Carbon Filter Syste
1 x Aeroponics HighPressure Booster Pump Aquatec CDP5853 Transformer
1 x Value Pack- Entire 3 Years of Replacement Filters Bundle K6ALK
1 x 741-14, Diverter Valve for Countertop Water Units
1 x N-14-1M, Nipple Fitting connector between standard RO housing
1 x 205, 3rd stage solid carbon block filter (replace every 12month)

View Cart$2,387.63
Specials Log InCreate Account Checkout  Shopping Cart49 item(s)
1 x MK800, Maintenance kit for AR122, AR125, HK120, RD150, RO155
1 x KM701C, Special Koolermax Filter Housing Canister Casing 1/4 FPT
1 x 4064K Male Connector Elbow 3/8 OD Compression Fitting 1/4 NPT
1 x 532b, PAE RO Water Storage Pressure Osmosis Tank Container 4G
2 x 201, 1st stage sediment filter (replace every 6-12 months)
1 x 733, Built-in Pressure Gauge 0 to 150 psi for Koolermax RO syste
1 x 205 2nd stage solid carbon block filter (replace every 12 month)
1 x Value Pack- Entire 3 Years of Replacement Filters Bundle RO155
1 x SV-24DC-38-Brass KSD Solenoid Valve 3/8" brass 24V DC ESO
1 x TMR-DC-1212, Transformer Power Supply for Delivery Demand Pump
1 x 7044-K Union Tee Connector Fitting Compression type 1/4"
1 x O-RING RINGS FOR WH20 WHOLE HOUSE SYSTEM HOUSING BIG BLUE 20"
1 x Optional 5th or 6th Stage upgrade inline DI filter(color change)
2 x PSW-260 Aquatec Pressure Switch 60 psi shut off 1/4" tubing TSO
1 x PSW-360 Aquatec Pressure Switch 60 psi shut off 3/8" tubing TSO
1 x KF320UP, SUBSTITUTE/Upgrade Faucet BRUSHED NICKEL STAINLESS STEE
1 x FPK11, High Quality Fitting and Connector 1/4" (Value-Pack)
1 x 6044-combo Compression Type Fitting Elbow and Tee fitting
2 x DB40, DI Resin Refill Bag for DI210, RD322
1 x PSW-240 Aquatec Pressure Switch 40 psi shut off 1/4" tubing TSO
1 x MK8002, Maintenance kit for double membrane system RD322 RO260
1 x Wrench 2 pcs 566 Standard Filter Housing Opener Double Better
1 x 4th stage TFC150 US membrane filter (every 2-3 yrs)M150 P/N3150
1 x 316, 2nd stage CTA 16 US Membrane filter
1 x B2010, 20" Big Blue Filter Housing Cartridge WH20 WH25 WH250
1 x .AR150PNTF, KoolerMax AR150P RO System Shell without tank faucet
1 x ACT-820-JG Aquatec Pulsation Dampener Accumulator Pressure Tank
1 x PSW-340 Aquatec Pressure Switch 40 psi shut off 3/8" tubing TSO
1 x AMTU-0404 Male Tee Union Connector NPT Thread 1/4" Quick Connect
1 x Value Pack- Entire 3 Years of Replacement Filters Bundle RD150
1 x Special, Output Conversion Kit Convert from 1/4" to 3/8"
1 x 727, Feed Water Adapter 3/8" compression adapter 1/4" inline bal
1 x 701, FH1014 Filter Housing Chamber Casing White Color 1/4 FPT
1 x SV-24AC-14, Solenoid Valve for Aquatec pump only 1/4" 24VAC ESO
1 x CP-OR35+701 O-RING FOR WATERGENERAL BOTTOM FILTER HOUSING CASING
1 x 6044-K Tee Fitting Compression Type 1/4"OD 1/4" NPT
1 x 752set, DC Booster Pump Transformer Solenoid Pressure Switch All
1 x *Discontinued* RD106
1 x 5th or 6th Stage IC21 inline carbon filter (every 6 to 12 mons)
1 x 399, 4th stage TFC-100 US membrane filter (every 2-3 yrs)
1 x WH-250, Whole House Water Treatment Sediment Carbon Filter Syste
1 x Aeroponics HighPressure Booster Pump Aquatec CDP5853 Transformer
1 x Value Pack- Entire 3 Years of Replacement Filters Bundle K6ALK
1 x 741-14, Diverter Valve for Countertop Water Units
1 x N-14-1M, Nipple Fitting connector between standard RO housing
1 x 205, 3rd stage solid carbon block filter (replace every 12month)

View Cart$2,387.63
Information

Flow meter measurement accuracy:

All meters are built in the same way and use the same formula to calculate the flow rate. There are many situations that affect the accuracy of the measurements. Trying to avoid them would increase the accuracy.

1. If there are air bubbles in the lines. Usually this might occur when using a pump to transfer water.

2. Incidents when the flow of water is too slow or too fast that is out of the measuring range. This meter has a range of 0.45 gpm and 3.7 gpm. If the flow of water is sometimes falls out of range, then it can't be counted or measured.
If you are not able to modify your setup in any way to avoid the effects of inaccuracy. You can apply a correction factor to the measurement. For example, take two to three different measurement to find the correction factor for the total count. Use a container that you can tell it has 1 gallon, 2 gallons, and 5 gallons. Use a stop watch to time how much time it takes for the meter to advance 1 gallon. If it takes 70 seconds to advance 1 gallon, then do the same test again to see if the time is about 70 seconds again. Then do the same test for 2 gallons of water. The time should be about 2 times 70 seconds or 140 seconds. If you do this test few times, and the results are the same that means you have found the correction factor. So, the correction factor in this case is 70 sec/ 60sec = 1.1666. If the meter reads 125 gallons then the actual value is about 125 * 1.1666 = 146 gallons.


Please understand most digital flow meters measures similarly. Industrial grade or commercial grade high accuracy flow meter are hundreds and thousands of dollars. Using a simple correction factor you can achieve higher accuracy regardless of your setup.