Log In Log In  |  Checkout   |  32 item(s)
1 x Wrench 2 pcs 566 Standard Filter Housing Opener Double Better
1 x FPK, High Quality Fitting and Connector 3/8" (Value-Pack)
1 x 2542-K, Female Connector 1/4 OD 1/8 FNPT Compression Fitting
2 x 532w, PAE RO Storage Pressure Osmosis Water Tank Container 4G
1 x 335, 4th stage TFC 35/45 US membrane filter (every 2-3 years)
1 x MK225, Maintenance kit for Honeywell RO9100 Filtercold RO5 AV180
1 x CBV-0404, Tank Ball Valve to 1/4 tubing *standard RO tank size*
1 x 215, 5th or 6th Stage Refillable inline DI filter (color change)
1 x Optional: 566 Filter Housing Wrench Opener WaterGeneral System
1 x 205, 3rd stage solid carbon block filter (replace every 12 month
1 x 213, 5th or 6th stage inline carbon filter (replace in 12 mons)
1 x 818, DI Resin Refill Bag 16oz (good for up to three refills)
1 x 324, 4th stage TFC-24 US membrane filter (replace every 2-3 yrs)
1 x KM701C, Special Koolermax Filter Housing Canister Casing 1/4 FPT
1 x 310, 2nd stage CTA 10 US Membrane filter
2 x 205, 3rd stage solid carbon block filter (replace every 12month)
2 x 701, FH1014 Filter Housing Chamber Casing White Color 1/4 FPT
1 x Optional: 564 Membrane Filter Housing Wrench Opener
1 x B2010, 20" Big Blue Filter Housing Cartridge WH20 WH25 WH250
1 x 701C, FHC1014 Filter Housing Chamber Casing Clear Color 1/4 FPT
1 x 733, Built-in Pressure Gauge 0 to 150 psi for Koolermax RO syste
1 x 215, 5th or 6th Stage Refillable inline DI filter (color change)
1 x 752set, DC Booster Pump Transformer Solenoid Pressure Switch All
1 x 335UP, Upgrade Kit TFC 35 gal/day (includes US membrane filter)
1 x AMTU-0404 Male Tee Union Connector NPT Thread 1/4" Quick Connect
1 x FPK, 6 pcs Fitting Pack Union Connector 3/8 x 1/4 inch
1 x 2nd stage C10 carbon block filter (replace every 6-12 months)
1 x 1.SED2005, 1st stage sediment filter 20" inch for RD322 RO260
1 x Parts, Ro Water System Installation Parts Bag 1/4"

View Cart$806.95
Specials Log InCreate Account Checkout  Shopping Cart32 item(s)
1 x Wrench 2 pcs 566 Standard Filter Housing Opener Double Better
1 x FPK, High Quality Fitting and Connector 3/8" (Value-Pack)
1 x 2542-K, Female Connector 1/4 OD 1/8 FNPT Compression Fitting
2 x 532w, PAE RO Storage Pressure Osmosis Water Tank Container 4G
1 x 335, 4th stage TFC 35/45 US membrane filter (every 2-3 years)
1 x MK225, Maintenance kit for Honeywell RO9100 Filtercold RO5 AV180
1 x CBV-0404, Tank Ball Valve to 1/4 tubing *standard RO tank size*
1 x 215, 5th or 6th Stage Refillable inline DI filter (color change)
1 x Optional: 566 Filter Housing Wrench Opener WaterGeneral System
1 x 205, 3rd stage solid carbon block filter (replace every 12 month
1 x 213, 5th or 6th stage inline carbon filter (replace in 12 mons)
1 x 818, DI Resin Refill Bag 16oz (good for up to three refills)
1 x 324, 4th stage TFC-24 US membrane filter (replace every 2-3 yrs)
1 x KM701C, Special Koolermax Filter Housing Canister Casing 1/4 FPT
1 x 310, 2nd stage CTA 10 US Membrane filter
2 x 205, 3rd stage solid carbon block filter (replace every 12month)
2 x 701, FH1014 Filter Housing Chamber Casing White Color 1/4 FPT
1 x Optional: 564 Membrane Filter Housing Wrench Opener
1 x B2010, 20" Big Blue Filter Housing Cartridge WH20 WH25 WH250
1 x 701C, FHC1014 Filter Housing Chamber Casing Clear Color 1/4 FPT
1 x 733, Built-in Pressure Gauge 0 to 150 psi for Koolermax RO syste
1 x 215, 5th or 6th Stage Refillable inline DI filter (color change)
1 x 752set, DC Booster Pump Transformer Solenoid Pressure Switch All
1 x 335UP, Upgrade Kit TFC 35 gal/day (includes US membrane filter)
1 x AMTU-0404 Male Tee Union Connector NPT Thread 1/4" Quick Connect
1 x FPK, 6 pcs Fitting Pack Union Connector 3/8 x 1/4 inch
1 x 2nd stage C10 carbon block filter (replace every 6-12 months)
1 x 1.SED2005, 1st stage sediment filter 20" inch for RD322 RO260
1 x Parts, Ro Water System Installation Parts Bag 1/4"

View Cart$806.95
Information

Pressure switch does not shut off pump sometimes:

To make the pump turn on/off automatically, you need to have this combination: pump, transformer, pressure switch (TSO) and solenoid valve (ESO). If you only have a pump, transformer, and pressure switch, the pump will not be able to turn off by itself.

The pressure switch should be connected at the pure water output line, so that when the tank is full, it would shut off the pump. The solenoid valve should be connected in front of the pump, so when the tank is full, it can shut off the water supply.


Quantity of nozzles you have will play a factor as well. You’ll need to adjust the pressure setting on the pressure switch to accommodate your application and the quantity of nozzles. To do so, you’ll need to use a small hex wrench to turn the hex screw clockwise 1 to 2 turns; then turn on your pump and water; allow the pressure to build up. This may take a few minutes.

Quantity of nozzles you have will play a factor as well. You’ll need to adjust the pressure setting on the pressure switch to accommodate your application and the quantity of nozzles. To do so, you’ll need to use a small hex wrench to turn the hex screw clockwise 1 to 2 turns; then turn on your pump and water; allow the pressure to build up. This may take a few minutes.
Continue
Home  |   Specials  |   Log In  |   Create Account  |   Checkout  |   Shopping Cart