Log In Log In  |  Checkout   |  38 item(s)
1 x 752, DC Booster Pump w/ Transformer
1 x 532w, PAE RO Storage Pressure Osmosis Water Tank Container 4G
1 x CP-OR35+701 O-RING FOR WATERGENERAL BOTTOM FILTER HOUSING CASING
1 x 752set, DC Booster Pump Transformer Solenoid Pressure Switch All
1 x 201, 1st stage sediment filter (replace every 6-12 months)
1 x 532b, PAE RO Water Storage Pressure Osmosis Tank Container 4G
1 x MK550, Maintenance kit for RO585, RD102, RD106, RO6, K5, K6
1 x 701, FH1014 Filter Housing Chamber Casing White Color 1/4 FPT
1 x FK-BB10K3, Big Blue Filter Pack Bundle for WH-1030 Whole House
1 x KM701, Special Koolermax Filter Housing Canister Casing 1/4 FPT
1 x 818, DI Resin Refill Bag 16oz (good for up to three refills)
1 x 225UP, 5th stage Inline Alkaline upgrade (includes media)
1 x 4th stage TFC150 US membrane filter (every 2-3 yrs)M150 P/N3150
1 x 5th Stage pn215 Refillable inline DI filter (color change)
1 x *Discontinued* RO155C
1 x HK120-PUMP KoolerMax Aeroponics Hydroponics System Booster Pump
1 x Annual Filter Kit Koolermax Series KPAK-3 Sediment Carbon Block
1 x 733, Built-in Pressure Gauge 0 to 150 psi for Koolermax RO syste
1 x SC725, Specialty Filter Chloramines / Hydrogen Sulfide Removal
1 x Special Filter Kit Koolermax dealer distribution kit
1 x SC208, Specialty Filter Iron Lead and Heavy Metal Removal Filter
1 x SC445, Specialty Filter SPECIAL ALKALINE FILTER Specialty Filter
1 x SC435, Specialty Filter Arsenic / Fluoride Removal Filter
1 x HK120-P-TK for USA 110V / 60Hz
1 x FK-BB20M3, Special Big Blue Filter Pack Bundle for WH350 WH-350
1 x SC412, Water Softening Filter Calcium Magnesium Hardness Removal
1 x 673, Replacement UV Lamp Light for 602 (6 Watts)
1 x .RO260 Aquarium 300G REVERSE OSMOSIS AEROPONICS HYDROPONICS RO
1 x SC209, Specialty Filter Nitrate Removal Filter
1 x 6th Stage pn215 Refillable inline DI filter (color change)
1 x Special, Output Conversion Kit Convert from 1/4" to 3/8"
1 x 1st stage SF05 sediment filter (replace every 6-12 months)
1 x UC SHELL, Honeywell UC7000 Empty System Only No Filter
1 x HK120-P-TK-220V for EURO 220V / 50Hz
1 x Wrench 2 pcs 566 Standard Filter Housing Opener Double Better
1 x SC207, Specialty Filter Refillable Color Changing DI Filter for
1 x 202,1 MICRON Sediment filter (replace every 6-12 month) SED1001
1 x 2nd stage C10 carbon block filter (replace every 6-12 months)

View Cart$2,531.49
Specials Log InCreate Account Checkout  Shopping Cart38 item(s)
1 x 752, DC Booster Pump w/ Transformer
1 x 532w, PAE RO Storage Pressure Osmosis Water Tank Container 4G
1 x CP-OR35+701 O-RING FOR WATERGENERAL BOTTOM FILTER HOUSING CASING
1 x 752set, DC Booster Pump Transformer Solenoid Pressure Switch All
1 x 201, 1st stage sediment filter (replace every 6-12 months)
1 x 532b, PAE RO Water Storage Pressure Osmosis Tank Container 4G
1 x MK550, Maintenance kit for RO585, RD102, RD106, RO6, K5, K6
1 x 701, FH1014 Filter Housing Chamber Casing White Color 1/4 FPT
1 x FK-BB10K3, Big Blue Filter Pack Bundle for WH-1030 Whole House
1 x KM701, Special Koolermax Filter Housing Canister Casing 1/4 FPT
1 x 818, DI Resin Refill Bag 16oz (good for up to three refills)
1 x 225UP, 5th stage Inline Alkaline upgrade (includes media)
1 x 4th stage TFC150 US membrane filter (every 2-3 yrs)M150 P/N3150
1 x 5th Stage pn215 Refillable inline DI filter (color change)
1 x *Discontinued* RO155C
1 x HK120-PUMP KoolerMax Aeroponics Hydroponics System Booster Pump
1 x Annual Filter Kit Koolermax Series KPAK-3 Sediment Carbon Block
1 x 733, Built-in Pressure Gauge 0 to 150 psi for Koolermax RO syste
1 x SC725, Specialty Filter Chloramines / Hydrogen Sulfide Removal
1 x Special Filter Kit Koolermax dealer distribution kit
1 x SC208, Specialty Filter Iron Lead and Heavy Metal Removal Filter
1 x SC445, Specialty Filter SPECIAL ALKALINE FILTER Specialty Filter
1 x SC435, Specialty Filter Arsenic / Fluoride Removal Filter
1 x HK120-P-TK for USA 110V / 60Hz
1 x FK-BB20M3, Special Big Blue Filter Pack Bundle for WH350 WH-350
1 x SC412, Water Softening Filter Calcium Magnesium Hardness Removal
1 x 673, Replacement UV Lamp Light for 602 (6 Watts)
1 x .RO260 Aquarium 300G REVERSE OSMOSIS AEROPONICS HYDROPONICS RO
1 x SC209, Specialty Filter Nitrate Removal Filter
1 x 6th Stage pn215 Refillable inline DI filter (color change)
1 x Special, Output Conversion Kit Convert from 1/4" to 3/8"
1 x 1st stage SF05 sediment filter (replace every 6-12 months)
1 x UC SHELL, Honeywell UC7000 Empty System Only No Filter
1 x HK120-P-TK-220V for EURO 220V / 50Hz
1 x Wrench 2 pcs 566 Standard Filter Housing Opener Double Better
1 x SC207, Specialty Filter Refillable Color Changing DI Filter for
1 x 202,1 MICRON Sediment filter (replace every 6-12 month) SED1001
1 x 2nd stage C10 carbon block filter (replace every 6-12 months)

View Cart$2,531.49
Information

Draining water ratio: 1:3:

The ratio of product to waste is a production rate to drain rate. If you put a pressure tank and measure how much waste water to fill the pressure tank, then the calculation is different. This ratio will be changing as it fills up the tank, since the drain rate is fixed at 500mL/min. and the production is decreasing as the tank fills up. So when the tank is empty, the ratio is 1:3, then as the tank fills up, it will be 1:4, 1:5 then it goes higher
until the tank is full.

Why did this happen? The pressure from the tank is pushing against the water. when the tank is empty, the tank pressure is 7 psi, as the tank fills up it goes higher so when the tank is almost full it can reach about 35 to 45 psi, so If you have 55 psi going into the RO, the net pressure across the membrane is 55-40 = 15 psi, that's why the system makes water slowly at the end.

If you wish to have less waste, you can purchase a smaller flow restrictor, so it limit the amount of water
going to the drain. However, there is a trade off. If you have less drain water, then the stage #4 membrane filter needs to be replaced more often. Also the TDS reading will be about 5 to 10 ppm higher after the 4th stage membrane. So you need to refill the DI resin more often.

The production rate of a RO system depends on your input pressure and water temperature, so when we say the ratio is 1:3 this is only approximation, it is not fixed. It depends on your water supply.

If you want the membrane to last longer, then have more drain. If saving water is more important, then use smaller flow restrictor and less drain. If you want both, then you need to add a booster pump or a permeate pump to the RO system.
Continue