Log In Log In  |  Checkout   |  30 item(s)
1 x Optional 225UP 5th stage Inline Alkaline upgrade(includes media)
1 x Value Pack- Entire 3 Years of Replacement Filters Bundle RD106
1 x Value Pack- Entire 3 Years of Replacement Filters Bundle AR122
2 x Wrench 2 pcs 566 Standard Filter Housing Opener Double Better
1 x 201, 1st stage sediment filter (replace every 6-12 months)
1 x 752, DC Booster Pump w/ Transformer
2 x 205, 3rd stage solid carbon block filter (replace every 12month)
1 x 752set, DC Booster Pump Transformer Solenoid Pressure Switch All
1 x 2.CB2010, 2nd stage carbon block filter 20" inch for RD322 RO260
1 x Conversion Kit, Convert Aquarium to Drinking RO Water System
1 x BUNDLE PACK Annual Filter Kit FK4 WaterGeneral 585 106 (4 ITEMS)
1 x Optional: 566 Filter Housing Wrench Opener WaterGeneral System
2 x 213, 5th or 6th stage inline carbon filter (replace in 12 mons)
1 x Value Pack- Entire 3 Years of Replacement Filters Bundle K6150P
1 x NM-5104, HONEYWELL COUNTERTOP WATER FILTER *DISCONTINUED* SW1
1 x 350UP, Upgrade Kit TFC50 gal/day (includes US membrane filter)
3 x Optional: 564 Membrane Filter Housing Wrench Opener
1 x 532b, PAE RO Water Storage Pressure Osmosis Tank Container 4G
1 x RF62, Replacement filter for CT-6000, UC7000, SW-1, and SW-1C
1 x 205 2nd stage solid carbon block filter (replace every 12 month)
1 x 732, Inline Pressure Gauge 0 to 300 psi for RO filter system
1 x 3rd stage C10 carbon block filter (replace every 6-12 months)
1 x 701C, FHC1014 Filter Housing Chamber Casing Clear Color 1/4 FPT
1 x 531, PAE RO Storage Pressure Osmosis Water Tank Container 3G
1 x 818, DI Resin Refill Bag 16oz (good for up to three refills)

View Cart$1,381.99
Specials Log InCreate Account Checkout  Shopping Cart30 item(s)
1 x Optional 225UP 5th stage Inline Alkaline upgrade(includes media)
1 x Value Pack- Entire 3 Years of Replacement Filters Bundle RD106
1 x Value Pack- Entire 3 Years of Replacement Filters Bundle AR122
2 x Wrench 2 pcs 566 Standard Filter Housing Opener Double Better
1 x 201, 1st stage sediment filter (replace every 6-12 months)
1 x 752, DC Booster Pump w/ Transformer
2 x 205, 3rd stage solid carbon block filter (replace every 12month)
1 x 752set, DC Booster Pump Transformer Solenoid Pressure Switch All
1 x 2.CB2010, 2nd stage carbon block filter 20" inch for RD322 RO260
1 x Conversion Kit, Convert Aquarium to Drinking RO Water System
1 x BUNDLE PACK Annual Filter Kit FK4 WaterGeneral 585 106 (4 ITEMS)
1 x Optional: 566 Filter Housing Wrench Opener WaterGeneral System
2 x 213, 5th or 6th stage inline carbon filter (replace in 12 mons)
1 x Value Pack- Entire 3 Years of Replacement Filters Bundle K6150P
1 x NM-5104, HONEYWELL COUNTERTOP WATER FILTER *DISCONTINUED* SW1
1 x 350UP, Upgrade Kit TFC50 gal/day (includes US membrane filter)
3 x Optional: 564 Membrane Filter Housing Wrench Opener
1 x 532b, PAE RO Water Storage Pressure Osmosis Tank Container 4G
1 x RF62, Replacement filter for CT-6000, UC7000, SW-1, and SW-1C
1 x 205 2nd stage solid carbon block filter (replace every 12 month)
1 x 732, Inline Pressure Gauge 0 to 300 psi for RO filter system
1 x 3rd stage C10 carbon block filter (replace every 6-12 months)
1 x 701C, FHC1014 Filter Housing Chamber Casing Clear Color 1/4 FPT
1 x 531, PAE RO Storage Pressure Osmosis Water Tank Container 3G
1 x 818, DI Resin Refill Bag 16oz (good for up to three refills)

View Cart$1,381.99
Information

Draining water ratio: 1:3:

The ratio of product to waste is a production rate to drain rate. If you put a pressure tank and measure how much waste water to fill the pressure tank, then the calculation is different. This ratio will be changing as it fills up the tank, since the drain rate is fixed at 500mL/min. and the production is decreasing as the tank fills up. So when the tank is empty, the ratio is 1:3, then as the tank fills up, it will be 1:4, 1:5 then it goes higher
until the tank is full.

Why did this happen? The pressure from the tank is pushing against the water. when the tank is empty, the tank pressure is 7 psi, as the tank fills up it goes higher so when the tank is almost full it can reach about 35 to 45 psi, so If you have 55 psi going into the RO, the net pressure across the membrane is 55-40 = 15 psi, that's why the system makes water slowly at the end.

If you wish to have less waste, you can purchase a smaller flow restrictor, so it limit the amount of water
going to the drain. However, there is a trade off. If you have less drain water, then the stage #4 membrane filter needs to be replaced more often. Also the TDS reading will be about 5 to 10 ppm higher after the 4th stage membrane. So you need to refill the DI resin more often.

The production rate of a RO system depends on your input pressure and water temperature, so when we say the ratio is 1:3 this is only approximation, it is not fixed. It depends on your water supply.

If you want the membrane to last longer, then have more drain. If saving water is more important, then use smaller flow restrictor and less drain. If you want both, then you need to add a booster pump or a permeate pump to the RO system.
Continue
Home  |   Specials  |   Log In  |   Create Account  |   Checkout  |   Shopping Cart