Log In Log In  |  Checkout   |  26 item(s)
1 x 3150, 5th stage TFC-150 US membrane filter (every 2-3 years)
1 x CP-KOR24, O-RING Oring FOR KOOLERMAX MEMBRANE FILTER HOUSING
1 x Optional: 564 Membrane Filter Housing Wrench Opener
1 x CBV-0404, Tank Ball Valve to 1/4 tubing *standard RO tank size*
1 x 4th stage TFC150 US membrane filter (every 2-3 yrs)M150 P/N3150
1 x 7044-K Union Tee Connector Fitting Compression type 1/4"
1 x 701, FH1014 Filter Housing Chamber Casing White Color 1/4 FPT
1 x 531, PAE RO Storage Pressure Osmosis Water Tank Container 3G
1 x OPTIONAL: 567 Filter Housing Wrench Case Opener WHOLE HOUSE WH
1 x FPK, High Quality Fitting and Connector 3/8" (Value-Pack)
1 x CKV0402, Blue color Elbow Check Valve Elbow Type
1 x UC SHELL, Honeywell UC7000 Empty System Only No Filter
1 x Y3414BR, Garden Hose Y Adapter Shutoff Valve Brass Construction
1 x CDP8800, AQUATEC CDP8852-2J03-B424 Booster Pump Only Fitting
1 x .RO260 Aquarium 300G REVERSE OSMOSIS AEROPONICS HYDROPONICS RO
1 x PSW-2100 Aquatec Pressure Switch 100 psi shut off 1/4 tubing TSO
1 x 913, 5th stage inline carbon filter (every 12 months)
1 x MK225, Maintenance kit for Honeywell RO9100 Filtercold RO5 AV180
1 x B2010, 20" Big Blue Filter Housing Cartridge WH20 WH25 WH250
1 x Optional 5th or 6th Stage upgrade inline DI filter(color change)
1 x DB40, DI Resin Refill Bag for DI210, RD322
1 x *Discontinued* RO585A
1 x SW SHELL, Countertop SW1 Empty System Only No Filter
1 x NM-5102, HONEYWELL COUNTERTOP WATER FILTER *DISCONTINUED* SW1
1 x 4044-K Male Elbow Fitting Compression type 1/4" OD 1/4" NPT
1 x Special, Output Conversion Kit Convert from 1/4" to 3/8"

View Cart$1,075.89
Specials Log InCreate Account Checkout  Shopping Cart26 item(s)
1 x 3150, 5th stage TFC-150 US membrane filter (every 2-3 years)
1 x CP-KOR24, O-RING Oring FOR KOOLERMAX MEMBRANE FILTER HOUSING
1 x Optional: 564 Membrane Filter Housing Wrench Opener
1 x CBV-0404, Tank Ball Valve to 1/4 tubing *standard RO tank size*
1 x 4th stage TFC150 US membrane filter (every 2-3 yrs)M150 P/N3150
1 x 7044-K Union Tee Connector Fitting Compression type 1/4"
1 x 701, FH1014 Filter Housing Chamber Casing White Color 1/4 FPT
1 x 531, PAE RO Storage Pressure Osmosis Water Tank Container 3G
1 x OPTIONAL: 567 Filter Housing Wrench Case Opener WHOLE HOUSE WH
1 x FPK, High Quality Fitting and Connector 3/8" (Value-Pack)
1 x CKV0402, Blue color Elbow Check Valve Elbow Type
1 x UC SHELL, Honeywell UC7000 Empty System Only No Filter
1 x Y3414BR, Garden Hose Y Adapter Shutoff Valve Brass Construction
1 x CDP8800, AQUATEC CDP8852-2J03-B424 Booster Pump Only Fitting
1 x .RO260 Aquarium 300G REVERSE OSMOSIS AEROPONICS HYDROPONICS RO
1 x PSW-2100 Aquatec Pressure Switch 100 psi shut off 1/4 tubing TSO
1 x 913, 5th stage inline carbon filter (every 12 months)
1 x MK225, Maintenance kit for Honeywell RO9100 Filtercold RO5 AV180
1 x B2010, 20" Big Blue Filter Housing Cartridge WH20 WH25 WH250
1 x Optional 5th or 6th Stage upgrade inline DI filter(color change)
1 x DB40, DI Resin Refill Bag for DI210, RD322
1 x *Discontinued* RO585A
1 x SW SHELL, Countertop SW1 Empty System Only No Filter
1 x NM-5102, HONEYWELL COUNTERTOP WATER FILTER *DISCONTINUED* SW1
1 x 4044-K Male Elbow Fitting Compression type 1/4" OD 1/4" NPT
1 x Special, Output Conversion Kit Convert from 1/4" to 3/8"

View Cart$1,075.89
Information

Draining water ratio: 1:3:

The ratio of product to waste is a production rate to drain rate. If you put a pressure tank and measure how much waste water to fill the pressure tank, then the calculation is different. This ratio will be changing as it fills up the tank, since the drain rate is fixed at 500mL/min. and the production is decreasing as the tank fills up. So when the tank is empty, the ratio is 1:3, then as the tank fills up, it will be 1:4, 1:5 then it goes higher
until the tank is full.

Why did this happen? The pressure from the tank is pushing against the water. when the tank is empty, the tank pressure is 7 psi, as the tank fills up it goes higher so when the tank is almost full it can reach about 35 to 45 psi, so If you have 55 psi going into the RO, the net pressure across the membrane is 55-40 = 15 psi, that's why the system makes water slowly at the end.

If you wish to have less waste, you can purchase a smaller flow restrictor, so it limit the amount of water
going to the drain. However, there is a trade off. If you have less drain water, then the stage #4 membrane filter needs to be replaced more often. Also the TDS reading will be about 5 to 10 ppm higher after the 4th stage membrane. So you need to refill the DI resin more often.

The production rate of a RO system depends on your input pressure and water temperature, so when we say the ratio is 1:3 this is only approximation, it is not fixed. It depends on your water supply.

If you want the membrane to last longer, then have more drain. If saving water is more important, then use smaller flow restrictor and less drain. If you want both, then you need to add a booster pump or a permeate pump to the RO system.
Continue
Home  |   Specials  |   Log In  |   Create Account  |   Checkout  |   Shopping Cart