Log In Log In  |  Checkout   |  29 item(s)
1 x Parts, Ro Water System Installation Parts Bag 1/4"
1 x UU Clips Pair Membrane to Filter, 2.5" to 2"
1 x PSW-350, Pressure Switch for RO Booster Pump 1/4" TSO
1 x 671C, Replacement UV Lamp Light for 609C (16 Watt)
1 x DM-1, Inline Dual TDS monitor (meter) for RO DI System DM1
1 x Optional 5th or 6th Stage upgrade inline DI filter(color change)
1 x SV-24DC-38-Plastic, KSD Solenoid Valve 3/8" 24V DC ESO
1 x PSW-360 Aquatec Pressure Switch 60 psi shut off 3/8" tubing TSO
1 x 578, TDS Water Quality Meter tds-3
1 x 5th stage 225 Inline Alkaline filter with clear housing (annual)
1 x 701, FH1014 Filter Housing Chamber Casing White Color 1/4 FPT
1 x MK800, Maintenance kit for AR122, AR125, HK120, RD150, RO155
1 x IM60, Ice Maker or RV Water Filter, Inline Typle
1 x Special, Single Stage Housing Bracket Shell Connection Kit
1 x 578b, TDS-3 Battery Batteries for #578 TDS Water Quality Meter
1 x SET88 Aquatec 8852 AC Booster pump Solenoid ESO Pressure Switch
1 x 310, 2nd stage CTA 10 US Membrane filter
1 x 205, 3rd stage solid carbon block filter (replace every 12month)
1 x 5th or 6th Stage IC21 inline carbon filter (every 6 to 12 mons)
1 x EMT-10, Empty Filter Cartridge Casing Housing
1 x 4042-K Male Elbow Fitting Compression type(membrane housing use)
1 x WH1134 Whole House Restaurant Filter System Sediment Carbon Big
1 x Optional: 564 Membrane Filter Housing Wrench Opener
1 x CBV-38, Tank Ball Valve to 3/8 tubing
1 x SC227, Specialty Filter Refillable Color Changing DI Filter 20"
1 x KM701C, Special Koolermax Filter Housing Canister Casing 1/4 FPT
1 x 3150, 4th stage TFC-150 US membrane filter (every 2-3 yrs)
1 x 2542-K, Female Connector 1/4 OD 1/8 FNPT Compression Fitting
1 x 759, Aquatec Demand Delivery Pump 5853-7E12-J524 Commercial 1.7G

View Cart$1,000.49
Specials Log InCreate Account Checkout  Shopping Cart29 item(s)
1 x Parts, Ro Water System Installation Parts Bag 1/4"
1 x UU Clips Pair Membrane to Filter, 2.5" to 2"
1 x PSW-350, Pressure Switch for RO Booster Pump 1/4" TSO
1 x 671C, Replacement UV Lamp Light for 609C (16 Watt)
1 x DM-1, Inline Dual TDS monitor (meter) for RO DI System DM1
1 x Optional 5th or 6th Stage upgrade inline DI filter(color change)
1 x SV-24DC-38-Plastic, KSD Solenoid Valve 3/8" 24V DC ESO
1 x PSW-360 Aquatec Pressure Switch 60 psi shut off 3/8" tubing TSO
1 x 578, TDS Water Quality Meter tds-3
1 x 5th stage 225 Inline Alkaline filter with clear housing (annual)
1 x 701, FH1014 Filter Housing Chamber Casing White Color 1/4 FPT
1 x MK800, Maintenance kit for AR122, AR125, HK120, RD150, RO155
1 x IM60, Ice Maker or RV Water Filter, Inline Typle
1 x Special, Single Stage Housing Bracket Shell Connection Kit
1 x 578b, TDS-3 Battery Batteries for #578 TDS Water Quality Meter
1 x SET88 Aquatec 8852 AC Booster pump Solenoid ESO Pressure Switch
1 x 310, 2nd stage CTA 10 US Membrane filter
1 x 205, 3rd stage solid carbon block filter (replace every 12month)
1 x 5th or 6th Stage IC21 inline carbon filter (every 6 to 12 mons)
1 x EMT-10, Empty Filter Cartridge Casing Housing
1 x 4042-K Male Elbow Fitting Compression type(membrane housing use)
1 x WH1134 Whole House Restaurant Filter System Sediment Carbon Big
1 x Optional: 564 Membrane Filter Housing Wrench Opener
1 x CBV-38, Tank Ball Valve to 3/8 tubing
1 x SC227, Specialty Filter Refillable Color Changing DI Filter 20"
1 x KM701C, Special Koolermax Filter Housing Canister Casing 1/4 FPT
1 x 3150, 4th stage TFC-150 US membrane filter (every 2-3 yrs)
1 x 2542-K, Female Connector 1/4 OD 1/8 FNPT Compression Fitting
1 x 759, Aquatec Demand Delivery Pump 5853-7E12-J524 Commercial 1.7G

View Cart$1,000.49
Information

Draining water ratio: 1:3:

The ratio of product to waste is a production rate to drain rate. If you put a pressure tank and measure how much waste water to fill the pressure tank, then the calculation is different. This ratio will be changing as it fills up the tank, since the drain rate is fixed at 500mL/min. and the production is decreasing as the tank fills up. So when the tank is empty, the ratio is 1:3, then as the tank fills up, it will be 1:4, 1:5 then it goes higher
until the tank is full.

Why did this happen? The pressure from the tank is pushing against the water. when the tank is empty, the tank pressure is 7 psi, as the tank fills up it goes higher so when the tank is almost full it can reach about 35 to 45 psi, so If you have 55 psi going into the RO, the net pressure across the membrane is 55-40 = 15 psi, that's why the system makes water slowly at the end.

If you wish to have less waste, you can purchase a smaller flow restrictor, so it limit the amount of water
going to the drain. However, there is a trade off. If you have less drain water, then the stage #4 membrane filter needs to be replaced more often. Also the TDS reading will be about 5 to 10 ppm higher after the 4th stage membrane. So you need to refill the DI resin more often.

The production rate of a RO system depends on your input pressure and water temperature, so when we say the ratio is 1:3 this is only approximation, it is not fixed. It depends on your water supply.

If you want the membrane to last longer, then have more drain. If saving water is more important, then use smaller flow restrictor and less drain. If you want both, then you need to add a booster pump or a permeate pump to the RO system.
Continue
Home  |   Specials  |   Log In  |   Create Account  |   Checkout  |   Shopping Cart